steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 weeks ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part number | LC1D09M7 |
| Manufacturer | Schneider |
| Product type | TeSys Deca contactor |
| Device designation | LC1D |
| Main application | Designed for motor control and resistive load switching |
| Utilisation category | AC-1, AC-3, AC-3e, AC-4 |
| Number of poles | 3-pole |
| Main contact arrangement | 3 normally open (3 NO) power contacts |
| Auxiliary contact arrangement | 1 normally open + 1 normally closed (1 NO + 1 NC) |
| Rated operational current (AC-3) | 9 A at up to 440 V AC |
| Rated operational current (AC-3e) | 9 A at up to 440 V AC |
| Conventional free-air thermal current (AC-1) | 25 A |
| Rated operational voltage | Up to 690 V AC, 25...400 Hz; up to 300 V DC |
| Control circuit type | AC coil, 50/60 Hz |
| Coil voltage | 220 V AC, 50/60 Hz |
| Motor power rating (AC-3) | 2.2 kW at 220...230 V AC; 4 kW at 380...440 V AC; 5.5 kW at 500...690 V AC |
| Motor power rating (AC-4) | 2.2 kW at 400 V AC |
| Horsepower rating | 1 hp at 230/240 V single-phase; 2 hp at 200/208 V and 230/240 V three-phase; 5 hp at 460/480 V three-phase; 7.5 hp at 575/600 V three-phase; 0.33 hp at 115 V single-phase |
| Rated insulation voltage (Ui) | 690 V |
| Rated impulse withstand voltage (Uimp) | 6 kV |
| Overvoltage category | III |
| Pollution degree | 3 |
| Rated making capacity | 250 A at 440 V for power circuit |
| Rated breaking capacity | 250 A at 440 V for power circuit |
| Rated short-time withstand current (Icw) | 105 A for 10 s; 210 A for 1 s; 61 A for 1 min; 30 A for 10 min on power circuit |
| Associated fuse rating | 25 A gG, coordination type 1; 20 A gG, coordination type 2; 10 A gG for signalling circuit |
| Coil inrush consumption | 70 VA at 50/60 Hz |
| Coil hold-in consumption | 7 VA at 50 Hz; 7.5 VA at 60 Hz |
| Heat dissipation | 2...3 W |
| Operating time | Closing: 12...22 ms; opening: 4...19 ms |
| Maximum operating rate | 3600 cycles/hour |
| Electrical durability | 0.6 million cycles at 25 A AC-1; 2 million cycles at 9 A AC-3 / AC-3e |
| Mechanical durability | 15 million cycles |
| Terminal type | Screw clamp terminals |
| Power circuit conductor size | 1...4 mm² flexible or solid; up to 2 x 1...4 mm² depending on conductor type |
| Control circuit conductor size | 1...4 mm² flexible or solid; up to 2 x 1...4 mm² depending on conductor type |
| Tightening torque | 1.7 N·m |
| Mounting method | Suitable for plate or DIN rail mounting |
| Front protection rating | IP20 |
| Protective treatment | TH |
| Ambient operating temperature | -40...60 °C, with derating up to 70 °C |
| Storage temperature | -60...80 °C |
| Operating altitude | Up to 3000 m |
| Fire resistance | 850 °C |
| Flame retardance | V1 according to UL 94 |
| Mechanical robustness | Vibration resistance: 2 Gn open, 4 Gn closed; shock resistance: 10 Gn open, 15 Gn closed |
| Dimensions | 77 mm height x 45 mm width x 86 mm depth |
| Net weight | 0.32 kg |
| Standards | IEC 60947-4-1, IEC 60947-5-1, EN 60947-4-1, EN 60947-5-1, UL 508, CSA C22.2 No. 14, IEC 60335-1 |
| Product certifications | Includes UL, CSA, CCC, UKCA, BV, DNV, GL, LROS, GOST and RINA |
| Protective cover | Fitted with protective cover |
This contactor is designed for switching and controlling electrical power circuits, particularly in motor control applications. It is well suited to panel builders and maintenance teams looking for a compact 3-pole device for AC motor duties and resistive loads.
Yes. It is intended for motor control and is rated for AC-3 and AC-3e duties, making it a practical choice for starting and switching three-phase motors within its electrical ratings.
The unit is rated at 9 A for AC-3 duty at up to 440 V AC and 25 A for AC-1 duty at up to 440 V AC. The power circuit is rated for up to 690 V AC and up to 300 V DC, depending on the application.
This version uses a 220 V AC 50/60 Hz coil. If you are matching an existing panel design, the LC1D09M7 should be checked against the control voltage already present in the circuit.
It has 3 main poles with 3 normally open main contacts. This makes it suitable for switching three-phase loads in a straightforward non-reversing arrangement.
Yes. It includes 1 normally open and 1 normally closed auxiliary contact as standard. These can be useful for interlocking, status indication or basic control logic within a panel.
Yes. In addition to motor control, it can also be used for resistive loads. Its AC-1 rating of 25 A makes it suitable for applications where the load characteristics are less demanding than motor starting.
Typical motor power ratings include 2.2 kW at 220 to 230 V AC, 4 kW at 380 to 440 V AC, and 5.5 kW at 500 to 690 V AC under AC-3 duty. Actual suitability should always be checked against the full application conditions.
It uses screw clamp terminals for both power and control wiring. This suits many conventional panel wiring layouts and allows connection of solid or flexible conductors within the stated cable size ranges.
This contactor can be mounted on a plate or on DIN rail, giving flexibility for new builds and replacement work in existing control panels.
The contactor is compact, with approximate dimensions of 77 mm high, 45 mm wide and 86 mm deep. Its net weight is around 0.32 kg, which helps when space is limited inside the enclosure.
No. This model does not include a built-in suppressor module as standard, so that should be considered if the application calls for additional control circuit noise suppression.
The front face has an IP20 protection rating. This means it is intended for installation inside a suitable enclosure or electrical assembly rather than exposed use.
It is designed to operate in ambient temperatures from -40 °C to 60 °C, with derating up to 70 °C. This makes it suitable for a wide range of industrial environments when installed correctly.
Yes. It has a maximum operating rate of up to 3600 cycles per hour at under 60 °C, making it a good fit for applications that involve regular switching within the stated duty limits.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.