steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 weeks ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part number | A9F74110 |
| Manufacturer | Schneider Electric |
| Product type | Miniature circuit breaker |
| Range | Acti9 |
| Product name | Acti9 iC60 |
| Model | iC60N |
| Poles | 1P |
| Protected poles | 1 |
| Rated current | 10 A |
| Tripping curve | C curve |
| Trip unit technology | Thermal-magnetic |
| Control type | Toggle |
| Network type | AC/DC |
| Network frequency | 50/60 Hz |
| Breaking capacity to EN/IEC 60898-1 | 6000 A at 230 V AC, 50/60 Hz |
| Breaking capacity to EN/IEC 60947-2 | 10 kA at 220...240 V AC, 50/60 Hz; 20 kA at 100...133 V AC, 50/60 Hz; 36 kA at 12...60 V AC, 50/60 Hz; 10 kA at up to 72 V DC; 15 kA at 12...60 V DC |
| Rated service breaking capacity (Ics) | 7.5 kA at 220...240 V AC, 50/60 Hz; 15 kA at 100...133 V AC, 50/60 Hz; 27 kA at 12...60 V AC, 50/60 Hz; 10 kA at 72 V DC; 15 kA at 12...60 V DC |
| Magnetic tripping limit | 8 x In ±20% |
| Utilisation category | Category A |
| Isolation suitability | Suitable for isolation |
| Standards | EN 60898-1, IEC 60898-1, EN 60947-2, IEC 60947-2 |
| Limitation class | Class 3 |
| Rated insulation voltage (Ui) | 500 V AC, 50/60 Hz |
| Rated impulse withstand voltage (Uimp) | 6 kV |
| Contact position indication | Yes |
| Local indication | Trip indicator |
| Mounting method | Fixed mounting |
| Mounting support | DIN rail |
| Busbar compatibility | Top or bottom comb busbar and distribution block compatible |
| Width in 9 mm modules | 2 |
| Dimensions (H x W x D) | 85 x 18 x 78.5 mm |
| Net weight | 0.215 kg |
| Terminal type | Single terminal, top or bottom |
| Cable size, rigid | 1...25 mm² |
| Cable size, flexible | 1...16 mm² |
| Wire stripping length | 14 mm |
| Tightening torque | 2 N.m |
| Earth-leakage protection | Without |
| IP rating | IP20 |
| Pollution degree | 3 |
| Overvoltage category | IV |
| Relative humidity | 95% at 55°C |
| Operating altitude | 0...2000 m |
| Operating temperature | -35...70°C |
| Storage temperature | -40...85°C |
| Colour | White |
| Mechanical durability | 20,000 cycles |
| Electrical durability | 10,000 cycles |
| Sustainability status | Green Premium product |
| RoHS status | Compliant |
| Mercury content | Mercury free |
| Halogen content | Halogen-free product |
| Packaging unit | 1 piece |
| Package dimensions | 2.0 x 7.5 x 9.5 cm |
| Package weight | 106.7 g |
This device is designed to protect distribution circuits against overloads and short circuits. It uses a thermal-magnetic trip mechanism, combining overload protection for sustained overcurrent conditions with magnetic tripping for higher fault currents.
It is a 1-pole miniature circuit-breaker rated at 10 A with a C curve. For AC applications, it is rated up to 240 V AC, with a 6 kA breaking capacity under IEC/EN 60898-1 and up to 10 kA under IEC/EN 60947-2 at 220 to 240 V AC.
A C curve breaker is commonly chosen for circuits where moderate inrush current may occur, such as general commercial and industrial branch circuits. On this unit, the magnetic tripping limit is 8 x In +/- 20%, helping it tolerate brief start-up currents better than a more sensitive curve.
Yes. This is a 1-pole device intended for protection of a single live conductor in suitable AC or DC distribution applications, subject to the installation requirements and the relevant electrical standard.
Yes. It is designed for fixed mounting on a DIN rail, making it suitable for use inside standard distribution boards and control panels where DIN rail installation is required.
The breaker measures 85 mm high, 18 mm wide and 78.5 mm deep. It occupies 2 modules of 9 mm pitch, which is useful when planning panel space.
The terminals accept single rigid conductors from 1 to 25 mm² and flexible conductors from 1 to 16 mm². The recommended wire stripping length is 14 mm, and the tightening torque is 2 N.m for top or bottom connection.
Yes. The terminal arrangement supports top or bottom connection, and it is also compatible with comb busbar and distribution block connection from either side.
No. This is a standard miniature circuit-breaker without earth-leakage protection. Its purpose is overcurrent and short-circuit protection rather than residual current protection.
Yes. The unit includes local trip indication as well as contact position indication, which helps users identify its status directly on the device.
It is specified in line with EN 60898-1 and IEC 60898-1, as well as EN 60947-2 and IEC 60947-2. This makes it suitable for a range of low-voltage distribution applications where these standards are relevant.
The device has an IP20 protection rating. It is intended for installation within an appropriate enclosure or panel environment rather than exposed use.
This miniature circuit-breaker is rated for operation in ambient temperatures from -35°C to 70°C and for storage from -40°C to 85°C. It is also specified for use at operating altitudes up to 2000 m and relative humidity up to 95% at 55°C.
Yes. It is specified as suitable for isolation in accordance with the relevant IEC and EN standards listed for the product.
The unit has a rated insulation voltage of 500 V AC and a rated impulse withstand voltage of 6 kV. These figures reflect the insulation and transient withstand characteristics declared for this model, including A9F74110.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.