steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | NSX100N |
| Manufacturer | Telemecanique |
| Product Type | Circuit Breaker |
| Device Short Name | ComPact NSX100N |
| Application | Distribution |
| Poles Description | 3P |
| Protected Poles Description | 3t |
| Rated Current [In] | 100 A at 40 °C |
| Rated Insulation Voltage [Ui] | 800 V AC 50/60 Hz |
| Rated Operational Voltage [Ue] | 690 V AC 50/60 Hz |
| Rated Impulse Withstand Voltage [Uimp] | 8 kV |
| Breaking Capacity Code | N |
| Breaking Capacity | 20 kA at 600 V AC 50/60 Hz (NEMA AB1, UL 508) |
| 50 kA at 480 V AC 50/60 Hz (NEMA AB1, UL 508) | |
| 85 kA at 240 V AC 50/60 Hz (UL 508) | |
| 90 kA at 240 V AC 50/60 Hz (NEMA AB1) | |
| Icu 10 kA at 660/690 V AC 50/60 Hz (IEC 60947-2) | |
| Icu 35 kA at 525 V AC 50/60 Hz (IEC 60947-2) | |
| Icu 36 kA at 500 V AC 50/60 Hz (IEC 60947-2) | |
| Icu 50 kA at 380/415 V AC 50/60 Hz (IEC 60947-2) | |
| Icu 50 kA at 440 V AC 50/60 Hz (IEC 60947-2) | |
| Icu 90 kA at 220/240 V AC 50/60 Hz (IEC 60947-2) | |
| Service Breaking Capacity [Ics] | Ics 10 kA at 660/690 V AC 50/60 Hz (IEC 60947-2) |
| Ics 35 kA at 525 V AC 50/60 Hz (IEC 60947-2) | |
| Ics 36 kA at 500 V AC 50/60 Hz (IEC 60947-2) | |
| Ics 50 kA at 380/415 V AC 50/60 Hz (IEC 60947-2) | |
| Ics 50 kA at 440 V AC 50/60 Hz (IEC 60947-2) | |
| Ics 90 kA at 220/240 V AC 50/60 Hz (IEC 60947-2) | |
| Suitability for Isolation | Yes, conforming to EN 60947-2 and IEC 60947-2 |
| Utilisation Category | Category A |
| Trip Unit Name | TM-D |
| Trip Unit Technology | Thermal-magnetic |
| Trip Unit Protection Functions | LI |
| Trip Unit Rating | 100 A (40 °C) |
| Protection Type | Overload protection (thermal), Short-circuit protection (magnetic) |
| Pollution Degree | 3 conforming to IEC 60664-1 |
| Control Type | Toggle |
| Mounting Mode | Fixed |
| Mounting Support | Backplate |
| Upside Connection | Front |
| Downside Connection | Front |
| Mechanical Durability | 50,000 cycles |
| Electrical Durability | 10,000 cycles at 690 V In, 20,000 cycles at 690 V In/2, 30,000 cycles at 440 V In, 50,000 cycles at 440 V In/2 |
| Connection Pitch | 35 mm |
| Local Signalling | Positive contact indication |
| Long Time Pick-up Adjustment Type [Ir] | Adjustable |
| Long Time Pick-up Adjustment Range | 0.7...1 x In |
| Long Time Delay Adjustment Type | Fixed |
| Long Time Delay Adjustment Range | 15 s 6 x Ir, 120...400 s 1.5 x In |
| Short Time Pick-up Adjustment Type [Isd] | Fixed |
| Short Time Pick-up Adjustment Range | 500 A |
| Short Time Delay Adjustment Type | Fixed |
| Height | 161 mm |
| Width | 105 mm |
| Depth | 86 mm |
| Product Weight | 2.05 kg |
| Electrical Shock Protection Class | Class II |
| Standards | EN 60947-2, IEC 60947-2, NEMA AB1, UL 508 |
| Product Certifications | CSA, UL |
| IP Degree of Protection | IP40 conforming to IEC 60529 |
| IK Degree of Protection | IK07 conforming to IEC 62262 |
| Ambient Air Temperature for Operation | -35...70 °C |
| Ambient Air Temperature for Storage | -55...85 °C |
| Sustainable Offer Status | Green Premium product |
| RoHS | Compliant |
| REACh | Reference not containing SVHC above the threshold |
| Product Environmental Profile | Available |
| Product End of Life Instructions | Need no specific recycling operations |
The rated current for the Telemecanique NSX100N circuit breaker is 100 A at 40°C.
The Telemecanique NSX100N offers both overload protection (thermal) and short-circuit protection (magnetic).
The rated operational voltage for the Telemecanique NSX100N is 690 V AC at 50/60 Hz.
The mechanical durability of the Telemecanique NSX100N is 50,000 cycles.
The electrical durability of the Telemecanique NSX100N is 10,000 cycles at 690 V In conforming to IEC 60947-2.
The dimensions of the Telemecanique NSX100N are 161 mm in height, 105 mm in width, and 86 mm in depth.
The weight of the Telemecanique NSX100N is 2.05 kg.
The Telemecanique NSX100N has an IP40 degree of protection conforming to IEC 60529.
The Telemecanique NSX100N conforms to EN/IEC 60947-2, NEMA AB1, and UL 508 standards.
The rated impulse withstand voltage for the Telemecanique NSX100N is 8 kV.
The rated insulation voltage for the Telemecanique NSX100N is 800 V AC at 50/60 Hz.
The ambient air temperature range for operation of the Telemecanique NSX100N is -35 to 70°C.
The ambient air temperature range for storage of the Telemecanique NSX100N is -55 to 85°C.
Yes, the Telemecanique NSX100N is suitable for isolation conforming to EN/IEC 60947-2.
The pollution degree for the Telemecanique NSX100N is 3, conforming to IEC 60664-1.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.