steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | 3RH1911-2FA31 |
| Alternative Part Number | 3RH19112FA31 |
| Manufacturer | Siemens |
| Product Brand Name | SIRIUS |
| Type | Auxiliary Switch Block |
| Configuration | 3 Normally Open (NO) + 1 Normally Closed (NC) contacts |
| Connection Type | Cage Clamp Connection |
| Mounting Type | Snap-on Mounting |
| Suitable For | Contactor Relays and Contactors for Switching Motors |
| Size | S00 |
| Operating Voltage | Up to 690 V Insulation Voltage |
| Impulse Voltage Resistance | Rated at 6 kV |
| Operating Current for AC-12 | 10 A at 24 V / 230 V |
| Operating Current for AC-15 | 6 A at 24 V / 230 V, 3 A at 400 V, 1 A at 690 V |
| Operating Current for DC-12 | 10 A at 24 V / 60 V, 4 A at 110 V, 2 A at 220 V |
| Operating Current for DC-13 | 6 A at 24 V, 2 A at 60 V, 1 A at 110 V, 0.3 A at 220 V |
| Mechanical Operating Cycles | Typically 10,000,000 |
| Electrical Operating Cycles | Typically 200,000 at AC-15 / 230 V |
| Ambient Operating Temperature | -25 to +60 °C during operation |
| Storage Temperature | -55 to +80 °C |
| Protection Class | IP20 on the front |
| Width | 36.5 mm |
| Height | 37.5 mm |
| Depth | 46 mm |
| Safety Features | Mirror contact according to IEC 60947-4-1, Positively driven operation according to IEC 60947-5-1 |
| Approvals | General Product Approval, Functional Safety/Safety of Machinery, Type Examination |
An auxiliary switch block is used to provide additional contact combinations for control and signalling functions within a control system. It is typically used in conjunction with contactor relays and power contactors for switching motors.
Yes, the 3RH1911-2FA31 auxiliary switch block is designed with features such as mirror contacts and positively driven operation, making it suitable for use in safety-related applications.
The auxiliary switch block supports cage clamp connections, which provide a secure and reliable connection for the auxiliary and control current circuits.
The auxiliary switch block can operate within an ambient temperature range of -25°C to +60°C for operating conditions, and -55°C to +80°C for storage conditions.
The auxiliary switch block is designed for typically 10 million mechanical operating cycles, indicating its durability and reliability for long-term use.
The insulation voltage rating for the auxiliary switch block is 690V with a degree of pollution 3, ensuring it can handle high-voltage environments safely.
The impulse voltage resistance of the auxiliary switch block is rated at 6kV, which helps to protect the circuit from voltage spikes.
The dimensions of the auxiliary switch block are 36.5mm in width, 37.5mm in height, and 46mm in depth, making it compact and suitable for various installation environments.
The protection class for the front of the auxiliary switch block is IP20, which provides protection against solid objects larger than 12.5mm but not against liquids.
The auxiliary switch block has 3 normally open (NO) contacts and 1 normally closed (NC) contact, providing flexibility in control circuit design.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.