steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
1 month ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Pepperl + Fuchs |
| Part Number | KFD2-ER-EX1.W.LB |
| Alternative Part Number | KFD2EREX1WLB |
| Part Type | Conductive switch amplifier |
| Device Function | 1-channel isolated barrier for conductive level sensing applications |
| Signal Type | Digital input |
| Supply Voltage | 20 to 30 V DC |
| Supply Connection | Power Rail or terminals 14+ and 15- |
| Rated Current | 30 to 40 mA |
| Input Connection | Field-side terminals 1, 2, and 3 |
| Input Configuration | Minimum/maximum control via terminals 1, 2, and 3; on/off control via terminals 1 and 3 |
| Response Sensitivity | Adjustable from 1 kΩ to 150 kΩ using the front potentiometer |
| Output Type | Relay contact output with additional fault relay contact output |
| Output Connection | Control-side terminals 7, 8, 9 and 10, 11, 12 |
| Switching Power | Maximum 192 W or 2000 VA |
| Contact Loading | 253 V AC at 2 A, cos φ greater than 0.7; 40 V DC at 2 A resistive load |
| Signal Damping | Selectable time constants of 0.5 s, 2 s, 5 s, or 10 s |
| Line Fault Detection | Lead breakage detection with red LED indication; selectable by DIP switch |
| Fault Resistor | 430 kΩ resistor used between the maximum and reference electrode for lead breakage detection |
| Display Elements | Green power LED, yellow relay output LED, and red lead breakage LED |
| Configuration Elements | DIP switch and potentiometer |
| Galvanic Isolation | Reinforced insulation between input/output, input/supply, and output/supply |
| Rated Insulation Voltage | 300 V effective according to IEC/EN 61010-1 |
| Hazardous Area Certificate | DMT 00 ATEX E 033 |
| ATEX Marking | II (1)G [EEx ia] IIC |
| Intrinsic Safety Input Rating | [EEx ia] IIC |
| Output Voltage Uo | 10 V |
| Output Current Io | 2.5 mA |
| Output Power Po | 6 mW |
| Maximum Safe Voltage Um | 40 V DC |
| Ambient Temperature | -20 °C to 60 °C |
| Degree of Protection | IP20 |
| Terminal Type | Screw terminals, maximum 2.5 mm² |
| Mounting | 35 mm DIN rail mounting according to EN 60715 |
| Dimensions | 20 mm x 119 mm x 115 mm |
| Housing Type | B2 |
| Approximate Mass | 150 g |
| Compatible Power Feed Module | KFD2-EB2 |
| Compatible Power Rail Options | UPR-03, UPR-03-M, and UPR-03-S |
| Compatible Terminal Blocks | KF-ST-5GN green 3-pin screw terminal and KF-ST-5BU blue 3-pin screw terminal |
| Commodity Code | 854370 |
It is a conductive switch amplifier used as a 1-channel isolated barrier for level sensing applications. It processes signals from conductive level electrodes and provides relay contact outputs for control-side switching.
This device is typically used for monitoring liquid levels with conductive electrodes, including on/off level control and minimum/maximum level control in industrial process environments.
The KFD2-ER-EX1.W.LB is designed for a 20 to 30 V DC rated supply and can be powered via Power Rail or through terminals 14+ and 15-.
The unit has a level sensing input for conductive electrodes. For minimum/maximum control, terminals 1, 2, and 3 are used; for on/off control, terminals 1 and 3 are used.
The device provides relay contact outputs on the control side. The relay output is suitable for switching loads up to 253 V AC at 2 A or 40 V DC at 2 A for resistive loads.
Yes. The unit includes lead breakage detection, often abbreviated as LB. When this function is enabled, a red LED indicates a detected line fault, and the second output can be used as a fault signal output.
Yes. The response sensitivity is adjustable from 1 kΩ to 150 kΩ using the front potentiometer, allowing the device to be matched to the conductivity of the measured medium.
Yes. The signal damping time constant can be selected using DIP switches. Available settings are 0.5 s, 2 s, 5 s, and 10 s.
The front LEDs indicate operating status: a green LED for power supply, a yellow LED for relay output status, and a red LED for lead breakage detection.
The switching behaviour is configured using DIP switch S1. The device can be set for open circuit current principle or closed circuit current principle, depending on the required relay action when the limit is reached.
The device is designed for mounting on a 35 mm DIN rail in accordance with EN 60715. Its compact housing is approximately 20 mm wide, making it suitable for dense control cabinet layouts.
The unit measures approximately 20 x 119 x 115 mm, with a mass of about 150 g. These dimensions correspond to a slim DIN rail module format.
The specified ambient operating temperature range is -20 °C to 60 °C, equivalent to -4 °F to 140 °F.
The device has an IP20 degree of protection. It is intended for installation inside a suitable control cabinet or enclosure.
The relay output connections are on the control side at terminals 7, 8, 9 and 10, 11, 12. These provide the switching contacts used by the connected control circuit.
Common associated accessories include KF series removable terminal blocks, coding pins, compatible Power Rail components, and DIN rail profile accessories for cabinet installation.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.