steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
2 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Pepperl+Fuchs |
| Part Number | 231393 |
| Model | KFD2-STC4-Ex1.H |
| Product Type | SMART transmitter power supply and isolated barrier |
| Number of Channels | 1 |
| Signal Type | Analog input |
| Supported Field Devices | 2-wire and 3-wire SMART transmitters; 2-wire SMART current sources |
| SMART Protocols | HART, BRAIN and Foxboro |
| Input Signal | 0/4–20 mA |
| Output Signal | 0/4–20 mA, with overload above 25 mA |
| Supply Voltage | 20–35 V DC |
| Supply Connection | Power Rail or terminals 14+ and 15− |
| Power Consumption | 1.9 W |
| Power Dissipation | 1.5 W |
| Available Field Voltage | At least 17.6 V at 20 mA using terminals 1+ and 3 |
| Output Load | 0–800 Ω at 20 mA |
| Internal HART Resistance | 250 Ω between terminals 8 and 9 |
| Output Ripple | Maximum 50 µA RMS |
| Signal Deviation | Maximum 10 µA at 20°C, including calibration, linearity, hysteresis, load and supply-voltage variations |
| Ambient Temperature Influence | 0.25 µA/K |
| Frequency Range | Field to control side: 0–7.5 kHz; control to field side: 0.3–7.5 kHz |
| Settling Time | 200 µs |
| Rise/Fall Time | 20 µs |
| Functional Safety Rating | SIL 2 in accordance with IEC 61508 |
| Hazardous-Area Application | Intrinsically safe interface for Zones 0, 1 and 2 and Divisions 1 and 2 |
| Galvanic Isolation | Input/output and input/power supply separation in accordance with IEC/EN 60079-11 |
| Status Indication | Green power LED |
| Test Facilities | Integrated terminal test points for HART communicators |
| Terminal Type | Removable screw terminals |
| Mounting | 35 mm DIN rail in accordance with EN 60715 |
| Degree of Protection | IP20 |
| Operating Temperature | −20 to 60°C |
| Dimensions | 20 × 124 × 115 mm |
| Housing Type | B2 |
| Approximate Mass | 200 g |
| Approvals | ATEX, IECEx and cULus |
It is a single-channel isolated barrier and SMART transmitter power supply designed to interface field instruments in hazardous areas with control equipment in a safe area.
The device supports 2-wire and 3-wire SMART transmitters, as well as 2-wire SMART current sources.
It accepts a 0/4 mA to 20 mA analogue input and transfers it to the control side as an electrically isolated 0/4 mA to 20 mA output.
Yes. Bidirectional HART communication can be superimposed on the analogue signal. Integrated test sockets also allow a HART communicator to be connected.
In addition to HART, the 231393 supports BRAIN and Foxboro SMART communication protocols.
The rated supply range is 20 V DC to 35 V DC. Power can be provided through the Power Rail or through terminals 14+ and 15-.
The output supports a load of 0 to 800 ohms at 20 mA.
The internal 250-ohm resistor between terminals 8 and 9 can be used when the loop resistance is too low for reliable HART communication.
The input and output, as well as the input and power supply, are galvanically isolated with a specified peak isolation value of 375 V. The output-to-power-supply connection has functional insulation rated at 50 V AC.
Yes. It is designed for intrinsically safe applications and carries ATEX, IECEx and cULus-related approvals for specified gas, dust and mining environments. Installation must follow the applicable certification and control documentation.
The specified ambient operating temperature range is -20°C to 60°C, and the enclosure has an IP20 rating.
It mounts on a standard 35 mm DIN rail in accordance with EN 60715. It can also connect to a compatible Power Rail arrangement.
The unit measures approximately 20 × 124 × 115 mm and has a mass of about 200 g.
A green LED indicates the power-supply status. The front panel also includes a labelling area and removable terminal blocks.
The device is rated up to SIL 2 in accordance with IEC 61508 when applied within the specified system design and operating conditions.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.