steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
2 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part number | 51140 |
| Manufacturer | Murr Elektronik |
| Manufacturer series / model | RMMD-2A/24VDC |
| Product type | Input relay module |
| Website description | Compact 24 VDC input relay module designed for reliable signal isolation and switching of higher-load circuits, featuring a single relay coil with two normally open contacts, status indication, and screw terminals for straightforward panel wiring. |
| Input (coil) rated voltage | 24 V DC |
| Input (coil) voltage range | 19.2…30 V DC |
| Input (coil) current | 15 mA |
| Output contact arrangement | 2 × normally open (NO) contacts (1 relay coil) |
| Maximum switching voltage | 250 V AC / 250 V DC |
| Maximum switching current | 2 A |
| Utilization category (DC-13, EN IEC 60947-5-1) | 0.8 A @ 24 V; 0.1 A @ 110 V; 0.01 A @ 230 V |
| Switching capacity (AC-12, EN IEC 60947-5-1) | 2 A (24/110/230 V AC) |
| Switching capacity (AC-15, EN IEC 60947-5-1) | 1 A (24 V AC); 0.1 A (230 V AC) |
| Max switching frequency | 15 Hz |
| Max breaking capacity (AC) | 125 VA |
| Max breaking capacity (DC) | 60 W |
| Minimum switching current (DC) | 0.1 mA |
| Status indication | Yellow LED |
| Typical response time (max) | 10 ms |
| Typical release time (max) | 10 ms |
| Contact bounce time (max) | 1 ms |
| Contact material | Ag Au |
| Rated impulse withstand voltage | 1.5 kV |
| Electrical life | 20,000,000 cycles (dependent on load) |
| Mechanical life | 20,000,000 cycles |
| Connection type | Screw terminals |
| Terminal / pin assignment (contacts) | 14–24 and 13–23 |
| Terminal / pin assignment (coil) | +A1 / −A2 |
| Mounting method | Snap-on mounting |
| DIN rail compatibility | TH35, G32 (EN 60715) |
| Operating temperature range | −25…+60 °C |
| Dimensions (H × W × D) | 82 × 12 × 68 mm |
| Weight | 0.041 kg |
| Country of origin | CZ |
| EAN | 4048879027731 |
| Commodity / HS code | 85364900 |
It provides electrical isolation between a 24 VDC control signal (coil/input) and a switched load on the output contacts, allowing a low-power control circuit to switch higher-voltage or higher-current circuits.
The coil is rated for 24 VDC. The permissible input range is 19.2 to 30 VDC, with a typical input current of 15 mA.
The output contacts can switch up to 250 VAC or 250 VDC, with a maximum switching current of 2 A (load-dependent).
It is a single relay with two normally open (NO) contacts.
Yes. A yellow LED indicates the relay coil/status for quick visual diagnostics in the panel.
Typical utilisation category ratings include AC-12: 2 A at 24/110/230 VAC; AC-15: 1 A at 24 VAC and 0.1 A at 230 VAC; DC-13: 0.8 A at 24 VDC, 0.1 A at 110 VDC, and 0.01 A at 230 VDC (per EN IEC 60947-5-1). Always size the relay to the actual load type (resistive vs inductive) and duty.
Maximum switching frequency is 15 Hz. Maximum breaking capacity is 125 VA (AC) and 60 W (DC).
Maximum response time is 10 ms and maximum drop-out time is 10 ms.
It is designed for snap-on mounting to standard DIN rails, including TH35 and G32 (EN 60715).
Approximate dimensions are 82 mm (height) × 12 mm (width) × 68 mm (depth), suitable for high-density DIN-rail assemblies.
It uses screw terminal connections, which are commonly preferred for secure field wiring in industrial control panels.
Yes. The module is supplied with a jumper (bridge) and includes a negative bridging plug concept, which can simplify commoning of the coil supply in multi-relay rows (refer to the included jumper category 90960).
The operating temperature range is -25 °C to +60 °C.
Mechanical life is specified at 20,000,000 cycles, and electrical life is specified at 20,000,000 cycles under the stated conditions (actual life depends on load type, switching energy, and duty cycle). For reference, this product is commonly identified as Murr Elektronik 51140.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.