steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
2 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | A1S64TCTT-S1 |
| Alternative Part Number | A1S64TCTTS1 |
| Manufacturer | Mitsubishi Electric |
| Series / Family | MELSEC-A (A Series) |
| Category | PLC Systems – Temperature Control Module |
| Product Description | 4-channel thermocouple temperature control module for MELSEC-A systems, providing closed-loop temperature regulation with transistor pulse outputs and configurable PID or two-position control. |
| Temperature Input Type | Thermocouple |
| Number of Input Channels | 4 channels per module |
| Supported Thermocouple Types | R, K, J, T, S, B, E, N, U, L, PL, W5Re/W26Re (range and resolution depend on selected input range) |
| Sampling Cycle | 0.5 s per 4 channels |
| Temperature Control Methods | PID control; ON/OFF pulse control; 2-position control |
| Auto-Tuning | Supported (PID auto-tuning available) |
| Proportional Band (P) | 0.0 to 1000.0% (0.0% = 2-position control) |
| Integral Time (I) | 1 to 3600 s |
| Derivative Time (D) | 1 to 3600 s (set 0 for PI control) |
| Control Output Type | Transistor output (ON/OFF pulse) |
| Control Output Cycle | 1 to 100 (setting range) |
| Rated Load Voltage (Output) | 10.2 to 30 VDC |
| Maximum Load Current (Output) | 0.1 A per point; 0.4 A per common |
| Maximum Inrush Current (Output) | 0.4 A (10 ms) |
| Output Voltage Drop (ON) | 0.1 VDC (typ.) at 0.1 A; 2.5 VDC (max.) at 0.1 A |
| Output Response Time | OFF→ON: < 2 ms; ON→OFF: < 2 ms (resistive load) |
| Input Impedance | 1 MΩ or more |
| Input Filter Setting | 1 to 100 s (0 = input filter off) |
| Sensor Compensation Setting | Software version A: -5.00 to +5.00%; version B or later: -50.00 to +50.00% |
| Operation on Input Disconnection | Upscale processing |
| Cold-Junction Compensation | Cold-junction compensation resistor supplied pre-installed on the terminal block |
| Insulation | Transformer insulation between thermocouple input and ground; transformer insulation between thermocouple input and channels |
| Accuracy (Reference) | At 23 ±5 °C: ±0.3% of full scale + 1 digit; at 0 to 55 °C: ±0.7% of full scale + 1 digit (overall accuracy includes cold-junction compensation accuracy) |
| Cold-Junction Compensation Accuracy (0 to 55 °C) | Temperature ≥ -100: within 1.0 °C; -150 to -100: within 2.0 °C; -200 to -150: within 3.0 °C |
| I/O Occupied Points | 32 points |
| Connection Terminal | 20-point terminal block |
| Supported Cable Size | 0.75 to 1.5 mm² |
| Supported Solderless Terminals | R1.25-3, 1.25-YS3, RAV1.25-3, V1.25-YS3A |
| Internal Current Consumption | 330 mA |
| Operating Ambient Temperature | 0 to 55 °C |
| Operating Ambient Humidity | 10 to 90% RH (non-condensing) |
| Dimensions (H × W × D) | 130 × 34.5 × 93.6 mm |
| Weight | 0.27 kg |
It provides closed-loop temperature control for up to four thermocouple input channels, performing measurement, alarm handling, and control output using control methods such as PID and ON/OFF (2-position) control.
It supports 4 independent thermocouple input channels per module.
This version is designed for thermocouple inputs (not platinum RTD inputs). Supported thermocouple types include R, K, J, T, S, B, E, N, U, L, PL, and W5Re/W26Re (ranges and resolution depend on the selected input range).
Ranges depend on the selected thermocouple type and input range setting. Depending on range, the module supports 0.1° or 1° data resolution (for example, Type K can be configured for ranges such as -200.0 to 400.0 with 0.1° resolution).
It provides transistor control outputs suitable for ON/OFF pulse control or 2-position control, enabling it to drive external control devices through appropriate interposing circuitry.
Rated load voltage is 10.2 to 30 VDC. Maximum load current is 0.1 A per point and 0.4 A per common. Maximum inrush current is 0.4 A for 10 ms. Response time is less than 2 ms for ON and less than 2 ms for OFF (resistive load).
No. This model is the version without heater disconnection detection. If you require heater disconnection detection, a different temperature control module variant with that function is typically used.
It supports PID control and ON/OFF (2-position) control. PID settings include proportional band, integral time, and derivative time, and auto-tuning can be used to assist with PID constant setup.
The sampling cycle is 0.5 seconds per 4 channels.
Yes. An input filter can be configured with a setting range of 1 to 100 seconds, or disabled (0) if filtering is not required.
If a thermocouple input is not connected or becomes disconnected, the module performs upscale processing, and the channel alarm indication can be triggered depending on the operating conditions.
Yes. Cold-junction compensation is provided, and the compensation resistor is shipped pre-installed to the terminal block.
RUN indicates module operating status (ON for normal operation, flashing patterns for specific errors, OFF when 5 V power is OFF). OUT indicates transistor output status (ON/OFF). ALM indicates alarm status (including conditions such as range exceeded or thermocouple not connected).
Use shielded compensating conductors for thermocouple wiring, keep sensor wiring separated from high-voltage and inverter/load wiring, and apply one-point grounding for the shield at the PLC side as appropriate for the noise environment.
Supported wire size is 0.75 to 1.5 mm². Supported solderless terminals include R1.25-3, 1.25-YS3, RAV1.25-3, and V1.25-YS3A.
It occupies 32 I/O points in the PLC system.
Approximate dimensions are 130 mm (H) × 34.5 mm (W) × 93.6 mm (D), and the weight is about 0.27 kg.
Typical installation is inside a control panel. Avoid locations outside the ambient temperature range of 0 to 55°C or humidity range of 10 to 90% RH (non-condensing), and avoid corrosive gases, conductive dust, strong electromagnetic fields, and direct vibration/shock transmission.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.