steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
2 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Danfoss |
| Part Number | 130B1212 |
| Option Type | VLT® General Purpose I/O MCB 101 |
| Product Category | General-purpose input/output option card |
| Application | Expands the control input and output capacity of compatible Danfoss VLT® frequency converters |
| Compatible Drive Series | VLT® HVAC Drive FC 102, VLT® Refrigeration Drive FC 103, VLT® AQUA Drive FC 202, and VLT® AutomationDrive FC 301/FC 302 |
| Digital Inputs | 3 inputs, 0–24 V DC |
| Digital Input Logic Levels | Logic 0 below 5 V; logic 1 above 10 V |
| Analogue Inputs | 2 voltage inputs, 0–10 V |
| Analogue Input Resolution | 10-bit plus sign |
| Digital Outputs | 2 configurable NPN/PNP push-pull outputs |
| Analogue Output | 1 output configurable for 0–20 mA or 4–20 mA |
| Connection Type | Spring-loaded terminals |
| Protective Treatment | Coated circuit board for enhanced resistance to demanding environmental conditions |
| Installation Position | Drive option slot B |
| Commodity Code | 853710 |
This is a Danfoss VLT General Purpose I/O MCB 101 option card designed to expand the control input and output capacity of compatible VLT frequency converters.
The card provides three 0–24 V digital inputs, two 0–10 V analogue inputs, two configurable NPN/PNP push-pull digital outputs, and one 0/4–20 mA analogue output.
Yes. Danfoss 130B1212 is the coated version of the MCB 101 General Purpose I/O card. The conformal coating provides additional protection for the electronic circuitry in demanding industrial environments.
The corresponding standard, uncoated MCB 101 option is Danfoss 130B1125. The environmental conditions and original drive configuration should be checked before substituting one version for the other.
The MCB 101 is listed for selected Danfoss VLT HVAC Drive FC 102, Refrigeration Drive FC 103, AQUA Drive FC 202, and AutomationDrive FC 301 and FC 302 frequency converters. Compatibility should be confirmed against the exact drive model and installed option arrangement.
It adds extra control points when the frequency converter's built-in terminals are insufficient. These additional channels can be used for external commands, references, feedback signals, status indication, and connections to other automation equipment.
The three digital inputs operate from 0–24 V. A signal below 5 V is interpreted as logic 0, while a signal above 10 V is interpreted as logic 1.
The two 0–10 V analogue inputs provide 10-bit resolution plus sign, allowing the drive to process external reference and feedback signals with suitable control precision.
The MCB 101 uses spring-loaded terminals. This connection method is intended to simplify control wiring and provide a secure connection within the frequency converter.
Yes. In specified VLT 5000 migration configurations, the MCB 101 can supply additional I/O channels needed to map signals that are not present on the FC 302 base control card.
Yes. It provides two digital outputs that can be configured for NPN or PNP push-pull operation, together with one analogue output supporting either 0–20 mA or 4–20 mA signalling.
Confirm the exact VLT drive series, enclosure configuration, available option slot, required terminal functions, and whether other option modules are already installed. Installation should be completed by personnel familiar with Danfoss frequency converters and industrial control wiring.
Typical applications include adding start and stop commands, reset inputs, preset references, process feedback, external status signals, and outputs for relays, indicators, PLC inputs, or other control devices.
The recorded commodity code is 853710, covering boards, panels, and similar assemblies used for electrical control or distribution at voltages not exceeding 1,000 V.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.