What is this cable used for?
It is an Industrial Ethernet/EtherCAT patch lead intended for robust, low-noise networking between compatible RJ45 ports, commonly used for short connections inside control cabinets and on machinery.
What is the cable length?
This variant is 0.17 m long (170 mm). In Beckhoff naming, this corresponds to ZK1090-9191-0001.
What connectors are fitted at each end?
It is RJ45 to RJ45 with straight, male 8‑pin plugs on both ends.
Is it shielded, and what does the shielding type mean?
Yes. The cable construction is SF/UTP, meaning it uses overall shielding (screen/foil) around unshielded twisted pairs to help reduce electromagnetic interference in industrial environments.
What Ethernet category/class does it meet?
It is specified as CAT 5, Class D performance, suitable for Industrial Ethernet and EtherCAT networks that rely on consistent signal integrity.
What is the conductor size and construction?
The cable uses 4 twisted pairs with an AWG26 conductor size (approximately 0.14 mm² per conductor), designed for industrial patching.
What is the outer jacket material and colour?
The outer sheath is PUR (polyurethane) in green (RAL 6018), chosen for durability in industrial installations.
What is the typical outer diameter of the cable?
The outer diameter is typically 5.9 mm (tolerance ±0.2 mm).
What bending radius should be observed?
For fixed installation, the minimum bending radius is 5x the cable diameter; for moved applications, it is 10x the cable diameter.
What temperature range can the cable operate in?
The specified ambient temperature range for the connectors is -40 to +85 °C. The cable is specified for operating temperatures up to around -40 to +80 °C for fixed installation, depending on the stated condition.
How many mating cycles are the connectors rated for?
The RJ45 plugs are specified for a minimum of 750 insertion (mating) cycles.
What are the electrical ratings of the connectors and cable?
The RJ45 connectors are rated at 160 V and 1 A (at 50 °C). The cable itself is rated at 60 V (per the stated cable specification).