steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
1 month ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | GJL1211009R0011 |
| Manufacturer | ABB |
| Manufacturer Reference / Model | B6-30-01-P-01 |
| Product Type | Mini contactor |
| Product Overview | Compact ABB mini contactor designed for space-conscious control panels, providing dependable switching of single- or three-phase loads with an integrated auxiliary contact and solder pin connections. |
| Poles | 3-pole |
| Main Contacts (NO) | 3 |
| Main Contacts (NC) | 0 |
| Auxiliary Contacts | 1 (NC) |
| Auxiliary Contacts (NO) | 0 |
| Rated Control Circuit Voltage (Uc) | 24 V AC |
| Control Circuit Frequency Range | 40–450 Hz |
| Coil Operating Limits (AC) | 0.85…1.1 × Uc (at +55 °C) |
| Rated Operational Voltage (Ue) – Main Circuit | Up to 690 V AC/DC (application dependent) |
| Rated Operational Voltage (Ue) – Auxiliary Circuit | 12…500 V AC/DC (application dependent) |
| Maximum Operating Voltage (UL/CSA) | Main circuit: 600 V AC; Auxiliary circuit: 600 V AC/DC |
| Rated Operational Current (Ie) – AC-1 | 12 A (220/240 V, 40–55 °C); 12 A (380/440 V, 40–55 °C); 6 A (690 V, 40–55 °C) |
| Rated Operational Current (Ie) – AC-3 (55 °C) | 8.5 A (220/230/240 V); 8.5 A (380/400 V); 7.4 A (440 V); 6.8 A (500 V); 3.8 A (690 V) |
| Rated Operational Power – AC-3 | 2.2 kW (220/230/240 V); 4 kW (400 V); 4 kW (440–500 V); 3 kW (690 V) |
| Conventional Free-Air Thermal Current (Ith) | 12 A |
| General Use Rating (UL/CSA) | 8 A at 300 V AC |
| Rated Insulation Voltage (Ui) | 690 V (IEC); 600 V (UL/CSA) |
| Impulse Withstand Voltage (Uimp) | 6 kV (main and auxiliary circuits) |
| Short-Time Withstand Current | 64 A for 10 s (at 40 °C, from cold state) |
| Making Capacity (AC-3) | 10 × Ie |
| Breaking Capacity (AC-3) | 8 × Ie |
| Maximum Electrical Switching Frequency | AC-1: 300 cycles/hour; AC-15: 600 cycles/hour; AC-3: 600 cycles/hour |
| Mechanical Durability | 10,000,000 cycles |
| Terminal Type | Soldering pins |
| Degree of Protection (Terminals) | IP20 (main, control, and auxiliary terminals) |
| Mounting | DIN rail TH35-7.5 and TH35-15 |
| Ambient Air Temperature (Operation) | -25…+55 °C |
| Maximum Operating Altitude | 2000 m |
| Resistance to Vibration (IEC 60068-2-6) | 5 g, 5…150 Hz |
| Resistance to Shock (IEC 60068-2-27) | 15 g, 11 ms pulse |
| Product Net Dimensions (W × H × D) | 47.5 mm × 45.5 mm × 51.5 mm |
| Product Net Weight | 0.17 kg |
| Compliance | RoHS in line with EU Directive 2011/65/EU |
| Standards | IEC/EN 60947-1; IEC/EN 60947-4-1; IEC/EN 60947-5-1; UL 60947-1; UL 60947-4-1 |
It is a compact mini contactor designed for switching and controlling electrical loads in space-constrained control panels. It is a 3-pole contactor with an integrated auxiliary contact and soldering pin terminals.
The rated control circuit (coil) voltage is 24 V AC. It is suitable for a wide AC frequency range (40–450 Hz), which can be helpful in specialised control power systems.
It has 3 main normally-open (NO) poles for the power circuit. It also includes 1 auxiliary normally-closed (NC) contact for signalling or interlocking.
It uses soldering pins, intended for PCB mounting or soldered connections rather than traditional screw clamp wiring.
Yes. It includes an integrated option for DIN rail mounting on TH35-7.5 and TH35-15 rails (35 mm top-hat profiles).
It is commonly used to control single-phase or three-phase loads such as small motors, heaters, lighting circuits, and control circuits where compact size and reliable switching are required.
For AC-3 motor switching duty, it is rated up to 4 kW at 400 V (three-phase). It is also commonly specified as 2.2 kW at 230/240 V and 3 kW at 690 V under AC-3 conditions.
For AC-1 (resistive) duty, typical rated operational current is 12 A at 220–440 V and 6 A at 690 V (ratings vary with ambient temperature).
Yes. Typical AC-15 ratings include 4 A at 24 V, 120 V, and 220/240 V (and 3 A at 380/400 V). For DC-13, typical ratings include 2.5 A at 24 V and 0.4 A at 220/240 V.
The main circuit is typically used up to 690 V AC/DC. The maximum operating voltage under UL/CSA is commonly stated as 600 V AC for the main circuit, with auxiliary circuits up to 600 V AC/DC.
The main, control, and auxiliary circuit terminals are rated IP20, meaning they are finger-safe in typical panel installations when correctly assembled.
Typical reference ambient air temperature for operation is from -25 °C to +55 °C, and permissible installation altitude is up to 2000 m.
Yes. It includes a switch position indication to show the contactor’s operating state.
Typical overall dimensions are approximately 47.5 mm (W) × 45.5 mm (H) × 51.5 mm (D), with a net weight around 0.17 kg. These figures are useful for enclosure layout and PCB or rail spacing.
Short-circuit protection is commonly coordinated using gG type fuses; a typical reference is 25 A (type 1 coordination), but final selection should be based on the application’s fault level and coordination requirements.
It is specified to common contactor standards including IEC/EN 60947-1, IEC/EN 60947-4-1, and IEC/EN 60947-5-1 (with corresponding UL 60947 references).
Many users reference the device marking “B6-30-01-P-01” and, where needed, the catalogue reference GJL1211009R0011 in internal BOMs and panel drawings to avoid ambiguity.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.