steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | 3TK2827-1BB40 |
| Alternative Part Number | 3TK28271BB40 |
| Manufacturer | Siemens |
| Category | General Automation |
| Supply Voltage | 24 V DC |
| Terminal Type | Screw Terminal |
| Mounting Type | Screw and snap-on mounting |
| Mounting Position | Any |
| Width | 44.8 mm |
| Height | 138.5 mm |
| Depth | 120 mm |
| Product Function | Monitored start-up, EMERGENCY OFF function, Pressure-sensitive mat monitoring |
| Safety Integrity Level (SIL) | SIL3 for basic functions, SIL2 for delayed release circuit |
| Performance Level (PL) | PL e for basic functions, PL d for delayed release circuit |
| Category according to EN ISO 13849-1 | 4 |
| Number of Sensor Inputs | 1-channel or 2-channel |
| Number of Outputs | 2 NO contacts for immediate actions, 2 NO contacts for delayed actions, 1 NC contact for signal |
| Operating Temperature Range | -25 to +60 °C |
| Storage Temperature Range | -40 to +80 °C |
| Installation Altitude | Up to 2000 m above sea level |
| Vibration Resistance | 5 to 500 Hz: 0.075 mm |
| Shock Resistance | 8g / 10 ms |
| Insulation Voltage | Rated value 300 V |
| EMC | Suitable for Class A environments only |
| Approvals | UL, CSA, TÜV, BG BIA |
| Commodity Code | 85364900 |
| Weight | 0.450 kg |
A safety relay is designed to provide a high level of safety for machine operators by monitoring safety devices and stopping machinery if an unsafe condition is detected. It is typically used in emergency stop circuits, safety gate monitoring, and light curtain applications.
Yes, the Siemens Safety Relay is suitable for emergency stop applications, ensuring that machinery is brought to a safe state when an emergency stop is activated.
The safety relay operates with a control supply voltage of 24 V DC, making it compatible with many industrial control systems that use this standard voltage level.
This safety relay is equipped with screw terminals, which provide a secure and reliable connection for wiring.
The Safety Integrity Level (SIL) rating indicates the reliability of the safety functions performed by the relay. This relay has a maximum achievable SIL of 3 for certain functions, which represents a high level of reliability and safety.
The maximum ambient operating temperature for the relay is 60°C, which allows it to function effectively in a range of industrial environments.
Yes, it is designed to monitor safety gates among other safety devices, ensuring that machinery remains in a safe state when safety gates are open.
The relay holds several certifications, including UL and CSA, which indicate compliance with North American safety standards, as well as TÜV and BG BIA certificates, which are recognised in European markets.
The relay has two normally open (NO) contacts for safety-related instantaneous actions and two NO contacts for safety-related delayed actions.
Yes, it is suitable for monitoring pressure-sensitive safety mats, which are used to detect the presence of persons or objects on the mat and trigger a safety response.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.