steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Siemens |
| Manufacturer Part Number (MPN) | 3RT2016-1AF02 (also written as 3RT20161AF02) |
| Product Range | SIRIUS |
| Device Type | Power contactor |
| Contactor Size | S00 |
| Product Description | Compact Siemens SIRIUS 3‑pole power contactor designed for dependable switching of three‑phase motors and other AC loads, featuring a 110 V AC control coil and screw terminal connections for straightforward panel wiring. |
| Main Poles | 3-pole |
| Main Contacts | 3 × NO (normally open) |
| Auxiliary Contacts (built-in) | 1 × NC (normally closed) |
| Utilisation Category | AC-3e / AC-3 |
| Rated Operational Current (AC-3) | 9 A at 400 V AC |
| Motor Rating (AC-3) | 4 kW at 400 V AC |
| Maximum Operational Voltage (AC-3/AC-3e) | Up to 690 V AC |
| Rated Current (AC-1) | 22 A at 400 V AC (40 °C) |
| Control Supply / Coil Voltage | 110 V AC, 50/60 Hz |
| Coil Operating Range Factor | 50 Hz: 0.8 … 1.1 × Un; 60 Hz: 0.85 … 1.1 × Un |
| Coil Apparent Power (Pick-up) | 27 VA (50 Hz); 24.3 VA (60 Hz) |
| Coil Apparent Power (Holding) | 4.2 VA (50 Hz); 3.3 VA (60 Hz) |
| Mounting | Screw mounting or snap-on to 35 mm DIN rail (DIN EN 60715) |
| Termination Type | Screw-type terminals (main, auxiliary and coil) |
| Connectable Conductor Cross-section (Main) | Solid/stranded: 0.5 … 4 mm²; finely stranded with end sleeve: 0.5 … 2.5 mm² |
| Connectable Conductor Cross-section (Auxiliary) | Solid/stranded: 0.5 … 4 mm²; finely stranded with end sleeve: 0.5 … 2.5 mm² |
| AWG Range (Main/Auxiliary) | 20 … 12 AWG |
| Degree of Protection (Front) | IP20 |
| Ambient Temperature (Operation) | -25 … +60 °C |
| Ambient Temperature (Storage) | -55 … +80 °C |
| Maximum Installation Altitude | 2,000 m above sea level |
| Mechanical Service Life (Typical) | 30,000,000 switching cycles |
| Dimensions (H × W × D) | 58 mm × 45 mm × 73 mm |
| Side-by-side Mounting | Yes |
| Recommended Clearance (side-by-side) | Forwards 10 mm; upwards 10 mm; downwards 10 mm; sides 0 mm |
| Commodity Code (HS) | 853649 |
It is a compact SIRIUS power contactor designed for switching three-phase AC loads, typically motor switching duties in AC-3/AC-3e applications. Typical motor rating is up to 4 kW at 400 V (AC-3).
For AC-3 motor switching, the operational current is 9 A at 400 V, with an operating power of 4 kW at 400 V. It is also commonly specified at 2.2 kW at 230 V and 5.5 kW at 690 V (AC-3).
It is a 3-pole contactor with 3 normally-open (NO) main power contacts for the main current circuit.
Yes. It includes 1 normally-closed (NC) auxiliary contact as standard.
The control coil is rated at 110 V AC, suitable for 50/60 Hz operation.
The coil operating range factor is typically 0.8 to 1.1 of rated voltage at 50 Hz and 0.85 to 1.1 at 60 Hz, which helps accommodate normal supply variations.
Typical apparent pick-up power is 27 VA at 50 Hz (about 24.3 VA at 60 Hz). Typical apparent holding power is 4.2 VA at 50 Hz (about 3.3 VA at 60 Hz).
It uses screw-type terminals for the main current circuit, the auxiliary contacts, and the coil connections.
Typical connectable conductor cross-sections for the main contacts are 0.5 to 4 mm² (solid or stranded). Finely stranded conductors with core end processing are typically 0.5 to 2.5 mm².
Typical connectable conductor cross-sections for the auxiliary/control terminals are 0.5 to 4 mm² (solid or stranded), and 0.5 to 2.5 mm² for finely stranded conductors with core end processing.
It can be screw-mounted or snapped onto a 35 mm DIN rail (DIN EN 60715). The device is designed for vertical mounting surfaces and allows a wide range of mounting orientations.
Typical dimensions are 58 mm (H) x 45 mm (W) x 73 mm (D), making it suitable for compact panel layouts (contactor size S00).
The front and terminal area are rated IP20, providing finger-safe protection from the front when installed correctly within a panel.
Typical operating ambient temperature range is -25 °C to +60 °C, with storage from -55 °C to +80 °C. Maximum installation altitude is typically 2,000 m above sea level.
Typical rated insulation voltage is 690 V, and rated impulse withstand (surge) voltage is 6 kV for both main and auxiliary circuits.
Typical maximum operating frequency is up to 750 operations per hour for AC-3 duties. For no-load switching, it can be significantly higher (typically up to 10,000 operations per hour), depending on application conditions.
The built-in NC auxiliary contact is commonly rated up to 10 A in AC-12. For AC-15, typical ratings include 10 A at 230 V and 3 A at 400 V. For DC-13, typical ratings include 1 A at 110 V and 0.3 A at 220 V.
In many installations, gG fuses are used for short-circuit protection of the main circuit. Typical guidance includes 35 A (coordination type 1) and 20 A (coordination type 2), with an auxiliary circuit fuse typically around 10 A gG. Final selection must match the installation design and applicable standards.
Yes, it can be used as a building block in a reversing arrangement, but reversing requires two contactors with appropriate electrical and mechanical interlocking to prevent simultaneous energisation.
No. This contactor variant does not include a communication function module. If communication is required, it is typically implemented at the control level rather than within this device.
Typical terminal designations are 1/L1, 3/L2, 5/L3 for incoming supply and 2/T1, 4/T2, 6/T3 for outgoing load, with A1 and A2 for the coil, and 21/22 for the NC auxiliary contact.
Yes. In addition to motor duty (AC-3/AC-3e), it can switch resistive loads under AC-1 conditions, where the permissible current is typically higher than the AC-3 motor rating (for example, around 22 A at 400 V in AC-1 at 40 °C ambient).
For panel thermal planning, typical power loss per pole can be low under rated motor duty (for example, around 0.7 W per conductor at AC-3, 400 V), but overall dissipation depends on load, duty cycle, and enclosure conditions.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.