steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 weeks ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | LR2K0307 |
| Manufacturer | Schneider |
| Product Type | Thermal Overload Relay |
| Relay Application | Motor Protection |
| Product Compatibility | LC1K, LP1K, LP4K, LC7K |
| Network Type | AC/DC |
| Thermal Overload Class | Class 10A conforming to IEC 60947-4-1 |
| Thermal Protection Adjustment Range | 1.2…1.8 A |
| Rated Insulation Voltage (Ui) | Power circuit: 690 V conforming to BS 4941, IEC 60947, 750 V conforming to VDE 0110 group C |
| Network Frequency | <= 400 Hz |
| Mounting Support | Under contactor, Plate with specific accessories, Rail with specific accessories |
| Auxiliary Contact Composition | 1 NO + 1 NC |
| Conventional Free Air Thermal Current (Ith) | 6 A for signalling circuit |
| Rated Operational Voltage (Ue) | <= 690 V for power circuit, 690 V AC AC-15 for signalling circuit, 250 V DC DC-13 for signalling circuit |
| Associated Fuse Rating | 6 A gG for signalling circuit conforming to VDE 0660, IEC 60947 |
| Rated Impulse Withstand Voltage (Uimp) | 6 kV |
| Power Dissipation Per Pole | 2 W |
| Phase Failure Sensitivity | Yes, conforming to IEC 60947-4-1 |
| Local Signalling | Trip indicator (yellow) |
| Control Type | Red push-button: trip test function, Blue push-button: stop and manual reset, Selector switch: manual or automatic reset |
| Connections - Terminals | Screw clamp terminals for cables 1.5…4 mm² solid and flexible, with and without cable end |
| Tightening Torque | 1.3 N.m - on screw clamp terminals with screwdriver Philips No 2, flat Ø 6 mm |
| Dimensions (Height x Width x Depth) | 58 mm x 45 mm x 65 mm |
| Product Weight | 0.145 kg |
| Standards | IEC 60947, NF C 63-650, VDE 0660, BS 4941 |
| Product Certifications | UL, CSA, UKCA |
| Protective Treatment | TC conforming to IEC 60068, TC conforming to DIN 50016 |
| IP Degree of Protection | IP2X conforming to IEC 60529 |
| Ambient Air Temperature for Operation | -20…55 °C without derating, -30…60 °C with derating |
| Ambient Air Temperature for Storage | -40…70 °C |
| Operating Altitude | 2000 m without derating |
| Fire Resistance | 850 °C conforming to IEC 60695-2-1 |
| Flame Retardance | V1 conforming to UL 94, Requirement 2 conforming to NF F 16-101, Requirement 2 conforming to NF F 16-102 |
| Mechanical Robustness | Shocks: 10 Gn for 11 ms, Vibrations: 2 Gn, 5...300 Hz, for both NO and NC contacts conforming to IEC 60068 |
| Sustainable Offer Status | Green Premium product |
| REACh Regulation | REACh Declaration, free of SVHC |
| EU RoHS Directive | Compliant |
| Mercury Free | Yes |
| China RoHS Regulation | China RoHS Declaration |
| Environmental Disclosure | Product Environmental Profile |
| End Of Life Information | Must be disposed on European Union markets following specific waste collection |
The overload relay is rated for ≤690 V ac, making it suitable for a wide range of industrial applications.
Yes, it is designed for DIN Rail mounting, which allows for easy installation and removal in control cabinets.
It features screw clamp terminals, which provide a secure and reliable connection for both solid and flexible wires.
The dimensions are 45 mm in width, 65 mm in depth, and 58 mm in height, making it compact enough for use in space-constrained environments.
The thermal protection adjustment range for this relay is 1.2 to 1.8 A.
This overload relay has an IP degree of protection of IP2X, providing protection against solid objects larger than 12.5 mm.
The ambient operating temperature range is from -20°C to 55°C without derating, ensuring reliable operation in various environmental conditions.
Yes, it includes phase failure sensitivity in accordance with IEC 60947-4-1, enhancing motor protection.
The conventional free air thermal current rating is 6 A for the signalling circuit.
Local signalling is managed through a trip indicator, which is a yellow indicator that provides visual confirmation of a trip event.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.