steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
1 month ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Schneider Electric |
| Part Number | A9F84106 |
| Product Type | Miniature circuit breaker |
| Range | Acti9 |
| Product Series | Acti9 iC60 |
| Device Short Name | iC60H |
| Application | Electrical distribution circuit protection |
| Poles | 1P |
| Protected Poles | 1 |
| Rated Current | 6 A |
| Curve Code | C curve |
| Trip Unit Technology | Thermal-magnetic |
| Network Type | AC/DC |
| Rated Operational Voltage | 240 V AC |
| Network Frequency | 50/60 Hz |
| Breaking Capacity | 10000 A Icn at 230 V AC according to EN/IEC 60898-1 |
| Rated Ultimate Breaking Capacity | 15 kA Icu at 220–240 V AC according to EN/IEC 60947-2 |
| Rated Service Breaking Capacity | 7.5 kA Ics at 220–240 V AC according to EN/IEC 60947-2 |
| Magnetic Tripping Limit | 8 x In ±20% |
| Utilisation Category | Category A |
| Isolation Suitability | Suitable for isolation according to EN/IEC 60898-1 and EN/IEC 60947-2 |
| Rated Insulation Voltage | 500 V AC |
| Rated Impulse Withstand Voltage | 6 kV |
| Limitation Class | Class 3 |
| Actuator Type | Toggle |
| Local Indication | Trip indicator |
| Contact Position Indicator | Yes |
| Mounting Type | Fixed |
| Mounting Support | DIN rail |
| Comb Busbar Compatibility | Top or bottom connection compatible |
| Terminal Capacity | 1–25 mm² rigid cable or 1–16 mm² flexible cable |
| Wire Stripping Length | 14 mm |
| Tightening Torque | 2 N·m |
| Earth Leakage Protection | Not included |
| IP Rating | IP20 |
| Pollution Degree | 3 |
| Overvoltage Category | IV |
| Operating Temperature | -35 to 70 °C |
| Storage Temperature | -40 to 85 °C |
| Relative Humidity | 95% at 55 °C |
| Operating Altitude | 0 to 2000 m |
| Mechanical Durability | 20000 cycles |
| Electrical Durability | 10000 cycles |
| Colour | White |
| Dimensions | 85 x 18 x 78.5 mm |
| Net Weight | 0.215 kg |
| Standards | EN 60898-1, IEC 60898-1, EN 60947-2, IEC 60947-2 |
| Sustainability Status | Green Premium product |
| RoHS Status | Compliant with exemptions |
| Mercury Free | Yes |
| Halogen Content | Halogen free |
It is a miniature circuit breaker designed for electrical distribution circuits. It uses a thermal-magnetic trip unit and a toggle actuator to help protect circuits against overloads and short circuits.
This device is a 1-pole miniature circuit breaker with one protected pole, making it suitable for single-pole circuit protection applications.
The rated current is 6 A.
It uses a C curve, which is commonly selected for circuits where moderate inrush currents may occur, such as certain control, lighting or small motor-related loads.
The product description lists it for 240 V AC use. The datasheet also specifies operation at 230 V AC and 220 to 240 V AC ratings depending on the applicable standard and breaking capacity.
Yes, the datasheet lists the network type as AC/DC and provides DC breaking capacity ratings. Suitability should always be checked against the circuit voltage, fault level and installation requirements.
The breaking capacity is listed as 10000 A Icn at 230 V AC under EN/IEC 60898-1.
The Icu rating is 15 kA at 220 to 240 V AC under EN/IEC 60947-2.
It is designed for fixed mounting on a DIN rail.
The unit measures approximately 85 mm high, 18 mm wide and 78.5 mm deep.
The terminals accept 1 to 25 mm² rigid conductors or 1 to 16 mm² flexible conductors, with top or bottom connection.
The specified wire stripping length is 14 mm for top or bottom connection.
The specified tightening torque is 2 N.m for the top or bottom terminals.
No. A9F84106 is listed as being without earth-leakage protection, so it functions as a miniature circuit breaker rather than an RCD or RCBO.
Yes, the device includes local signalling with a trip indicator, as well as a contact position indicator.
The datasheet references EN 60898-1, IEC 60898-1, EN 60947-2 and IEC 60947-2.
Yes, the datasheet states suitability for isolation in accordance with EN 60898-1, IEC 60898-1, EN 60947-2 and IEC 60947-2.
The degree of protection is IP20, conforming to IEC 60529 and EN 60529.
The operating ambient air temperature range is -35 °C to 70 °C.
The datasheet lists mechanical durability as 20000 cycles and electrical durability as 10000 cycles.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.