steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Schneider Electric |
| Part Number | 24440 |
| Extended Reference | A9K24440 |
| Product Range | Acti9 |
| Product Series | Acti9 iK60 |
| Product Type | Miniature circuit breaker |
| Device Short Name | iK60N |
| Application | Electrical distribution |
| Number of Poles | 4 |
| Protected Poles | 4 |
| Rated Current | 40 A at 30°C |
| Trip Curve | C curve |
| Trip Technology | Thermal-magnetic |
| Magnetic Tripping Range | 5–10 × rated current |
| Network Type | AC |
| Network Frequency | 50/60 Hz |
| Breaking Capacity | 6 kA at 400 V AC, in accordance with EN/IEC 60898-1 |
| Service Breaking Capacity | 6 kA at 400 V AC |
| Rated Insulation Voltage | 440 V AC |
| Impulse Withstand Voltage | 4 kV |
| Current Limitation Class | Class 3 |
| Isolation Suitability | Suitable for isolation in accordance with EN/IEC 60898-1 |
| Control Type | Toggle switching |
| Local Indication | ON/OFF position indication |
| Mounting Method | Clip-on |
| Mounting Support | DIN rail |
| Module Width | 8 × 9 mm pitches |
| Terminal Type | Tunnel terminals, top or bottom |
| Rigid Cable Capacity | 1–35 mm² |
| Flexible Cable Capacity | 1–25 mm² |
| Wire Stripping Length | 14 mm |
| Terminal Tightening Torque | 3.5 N·m |
| Mechanical Endurance | 20,000 operating cycles |
| Electrical Endurance | 10,000 operating cycles |
| Degree of Protection | IP20 |
| Pollution Degree | 2 |
| Overvoltage Category | Category II |
| Operating Temperature | -25°C to +60°C |
| Storage Temperature | -40°C to +85°C |
| Height | 85 mm |
| Width | 72 mm |
| Depth | 78.5 mm |
| Net Weight | 400 g |
| Colour | White |
| Applicable Standard | EN/IEC 60898-1 |
| Earth-Leakage Protection | Not included |
This is a Schneider Acti9 iK60N miniature circuit breaker designed to protect AC distribution circuits against overloads and short circuits.
The circuit breaker has a rated current of 40 A at an ambient reference temperature of 30°C.
It is a four-pole circuit breaker, with protection provided across all four poles.
The C curve provides magnetic tripping at approximately five to ten times the rated current. It is commonly used for circuits with moderate starting currents, including many industrial and commercial loads.
The rated short-circuit breaking capacity is 6,000 A at 400 V AC, 50/60 Hz, in accordance with EN/IEC 60898-1.
The device is intended for AC electrical distribution networks operating at 50 or 60 Hz.
No. This miniature circuit breaker provides overload and short-circuit protection but does not include earth-leakage protection. A separate residual-current device may be required where that function is needed.
The breaker uses a clip-on mounting arrangement for installation on a standard DIN rail.
The unit is 72 mm wide and occupies eight 9 mm modular pitches. Its overall dimensions are approximately 85 mm high, 72 mm wide and 78.5 mm deep.
The tunnel terminals accept rigid conductors from 1 to 35 mm² and flexible conductors from 1 to 25 mm². The specified wire stripping length is 14 mm.
The recommended tightening torque for the upper or lower terminals is 3.5 N·m.
The specified ambient operating temperature range is -25°C to 60°C. The storage temperature range is -40°C to 85°C.
The device has an IP20 protection rating in accordance with IEC 60529.
Yes. The circuit breaker is suitable for isolation in accordance with EN/IEC 60898-1 when correctly selected and installed.
The device is rated for 20,000 mechanical operating cycles and 10,000 electrical operating cycles under the specified conditions.
The front toggle provides local ON and OFF indication. However, the device does not include a separate positive contact-position indicator.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.