steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
1 month ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Omron |
| Part Number | H5CN-XCN |
| Product Type | Digital timer |
| Product Description | Four-digit electronic timer with an upward-counting display, thumbwheel time setting and power-on delay operation |
| Display Type | 7-segment red LED display |
| Number of Digits | 4 |
| Display Character Height | 8 mm |
| Timer Display Mode | UP counting, incrementing from zero to the preset time |
| Time Range | 1 second to 99 minutes 59 seconds |
| Setting Method | Thumbwheel switches |
| Output Mode | N: power-on delay |
| Rated Supply Voltage | 100–240 VAC, 50/60 Hz |
| Permitted Voltage Range | 85–110% of rated supply voltage |
| Power Consumption | Approximately 12 VA |
| Input Signals | Reset and gate |
| Input Method | No-voltage input |
| Minimum Input Signal Width | 20 ms |
| Reset Methods | Power reset and external reset |
| Minimum Power-Off Time | 0.5 seconds |
| Control Output | SPDT relay contact |
| Resistive Load Rating | 3 A at 250 VAC or 3 A at 24 VDC |
| Inductive Load Rating | 1 A at 250 VAC or 2.5 A at 24 VDC |
| Minimum Applicable Load | 10 mA at 5 VDC |
| Connection | 8-pin round socket |
| Mounting Method | Flush mounting or surface mounting |
| Front Dimensions | 48 × 48 mm |
| Protection Rating | IP30 at the panel surface |
| Operating Temperature | -10°C to +55°C, without icing or condensation |
| Storage Temperature | -25°C to +65°C, without icing or condensation |
| Operating Humidity | 35–85% RH |
| Insulation Resistance | At least 100 MΩ at 500 VDC |
| Dielectric Strength | 2,000 VAC at 50/60 Hz for 1 minute |
| Mechanical Endurance | At least 10,000,000 operations under no load |
| Electrical Endurance | At least 100,000 operations at 3 A, 250 VAC resistive load |
| Enclosure Colour | Light grey |
| Approximate Weight | 200 g |
It is an industrial digital timer designed to control an electrical output after a preset time interval.
The timer can be set from 1 second up to 99 minutes and 59 seconds.
The required time is entered using front-mounted thumbwheel switches, allowing the setting to be viewed and adjusted directly.
The H5CN-XCN uses an UP display, meaning the displayed value increases from zero towards the selected time.
It uses an N-mode power-ON delay. The timer begins counting when operating power is applied, and the control output changes state when the set time expires.
The unit has an SPDT relay contact output rated at up to 3 A at 250 VAC for a resistive load.
Reset and gate inputs are provided. These use no-voltage input signals with a minimum input width of 20 milliseconds.
Versions were produced for 100–240 VAC and 12–48 VDC supplies. The voltage rating printed on the unit should always be checked before installation.
It supports both flush panel mounting and surface mounting, making it suitable for control panels and industrial enclosures.
The timer connects through an 8-pin round socket. The socket terminal arrangement and existing panel wiring should be checked before fitting.
The timer has a compact 48 × 48 mm front profile commonly used for panel-mounted industrial timing devices.
It is rated for operation from -10°C to 55°C in environments without icing or condensation, with an operating humidity range of 35% to 85%.
For a power-ON start, the specified accuracy is within ±0.01% of the set value plus 0.05 seconds. For a reset start, it is within ±0.005% plus 0.03 seconds.
Typical uses include delayed machine start-up, timed process stages, conveyor sequencing, pump control, heating cycles and general control-panel automation.
For the 100–240 VAC version, Omron identifies the H5CC-L8 100–240 VAC as the recommended replacement. For the 12–48 VDC version, the corresponding option is the H5CC-L8D. Electrical connections, dimensions and operating settings should be compared before substitution.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.