steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 weeks ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | ABB |
| Part Number | ACH550-01-038A-4 |
| Alternative Part Number | ACH55001038A4 |
| Series | ACH550 |
| Product Type | Frequency Converter / Inverter Drive |
| Drive Category | Low-voltage AC inverter drive for HVAC applications |
| Rated Motor Power | 18.5 kW |
| Rated Output Current | 38 A |
| Supply Voltage | 3-phase, 380 to 480 V AC |
| Supply Frequency | 48 to 63 Hz |
| Frame Size | R3 |
| Enclosure Rating | IP21 / UL Type 1 |
| Overload Capacity | 110% for 1 minute every 10 minutes |
| Output Frequency Range | 0 to 500 Hz |
| Typical Applications | Variable speed control of standard asynchronous motors used with fans, pumps and HVAC plant equipment |
| Integrated Control Features | Sensorless vector control, PID control, ramp functions, motor protection monitoring and HVAC application macros |
| Standard Communications | RS-485 with BACnet MS/TP, Modbus RTU, N2 and FLN capability |
| Inputs | 2 analogue inputs and 6 digital inputs |
| Outputs | 2 analogue outputs and 3 relay outputs |
| EMC Performance | Integrated EMC filter designed to meet EN 61800-3 Class C2 requirements |
| Harmonics Compliance | Designed to meet IEC/EN 61000-3-12 requirements |
| Dimensions | 583 x 203 x 231 mm |
| Weight | 15.02 kg |
| Commodity Code | 850440 |
This is an ABB ACH550 series frequency converter, also known as an inverter drive or variable frequency drive. It is used to control the speed and torque of three-phase AC motors, particularly in building services and HVAC applications.
It is rated for a typical motor power of 18.5 kW, making it suitable for medium-sized motor control applications such as fans, pumps and air-handling equipment.
The drive is designed for a three-phase mains supply from 380 to 480 V AC, with a stated tolerance of +10% / -15%. It is intended for standard industrial and commercial low-voltage motor systems.
The rated output current is 38 A. The ACH550-01-038A-4 also allows short-term overload of 110% for 1 minute every 10 minutes across the speed range.
Yes. The ACH550 family is designed for HVAC and building automation duties, including speed control of fans, pumps and other motor-driven plant. It includes HVAC-focused control features and commonly used building communication protocols.
This model is an R3 frame size drive. In the IP21 / UL Type 1 configuration, the datasheet dimensions for the drive body are 583 mm high, 203 mm wide and 231 mm deep, with a listed weight of approximately 16 kg.
The standard wall-mounted version is IP21 / UL Type 1. An IP54 / UL Type 12 variant may be identified by the +B055 option code, but that is a different configuration from the base unit.
The ACH550 series includes RS-485 communication as standard, with protocols such as BACnet MS/TP, Modbus RTU, N2 and FLN. This makes it suitable for integration into many building management systems.
The drive provides 2 analogue inputs, 2 analogue outputs, 6 digital inputs and 3 relay outputs. These connections allow integration with sensors, setpoint signals, run commands, status indications and control circuits.
The motor output frequency range is 0 to 500 Hz, allowing flexible speed control for compatible three-phase AC motors when correctly selected and parameterised for the application.
The operating ambient temperature range is -15 to 50 °C, with no frost permitted. Rated output current is available up to 40 °C, with current derating above that temperature.
The drive includes functions such as overvoltage control, undervoltage control, earth-leakage supervision, motor short-circuit protection, overcurrent protection, phase-loss detection, underload supervision, overload supervision and stall protection.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.