steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 weeks ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Siemens |
| Part Number | 3RT1016-1AF01 |
| Alternative Part Number | 3RT10161AF01 |
| Product Type | Power contactor |
| Series / Range | SIRIUS |
| Contactor Size | S00 |
| Poles (Main Circuit) | 3-pole |
| Main Contacts Configuration | 3 NO (normally open) |
| Auxiliary Contacts (Built-in) | 1 NO (normally open), instantaneous |
| Rated Operational Current (AC-1) | 22 A at 400 V (40 °C) |
| Rated Operational Current (AC-3) | 9 A at 400 V |
| Rated Operational Current (AC-4) | 8.5 A at 400 V |
| Motor Power Rating (AC-3) | 4 kW at 400 V; 4.5 kW at 500 V; 5.5 kW at 690 V |
| Control Coil Voltage | 110 V AC |
| Coil Frequency | 50/60 Hz |
| Coil Operating Range Factor | 50 Hz: 0.8…1.1 × Un; 60 Hz: 0.85…1.1 × Un |
| Coil Apparent Power (Pick-up) | 27 VA |
| Coil Apparent Power (Holding) | 4.4 VA |
| Power Loss (AC-3) | 0.7 W per conductor at 400 V (rated operational current) |
| Protection Rating (Front / Terminals) | IP20 / IP20 |
| Pollution Degree | 3 |
| Ambient Temperature (Operation) | -25…+60 °C |
| Max Installation Altitude | 2000 m |
| Mechanical Service Life (Typical) | 30,000,000 switching cycles |
| Mounting | Screw mounting or snap-on mounting to 35 mm DIN rail (DIN EN 50022) |
| Side-by-side Mounting | Yes |
| Dimensions (H × W × D) | 57.5 mm × 45 mm × 72 mm |
| Required Side Clearance to Earthed Parts | 6 mm |
| Main Circuit Terminals | Screw-type terminals |
| Control & Auxiliary Terminals | Screw-type terminals |
| Connectable Conductor Cross-Section (Main) | Solid / stranded: up to 2 × (0.75…4 mm²); finely stranded with ferrule: 2 × (0.5…1.5 mm²) or 2 × (0.75…2.5 mm²) |
| Connectable Conductor Cross-Section (Aux/Control) | Solid: up to 2 × (0.75…4 mm²); finely stranded with ferrule: 2 × (0.5…1.5 mm²) or 2 × (0.75…2.5 mm²) |
| Auxiliary Contact Ratings (Typical) | AC-12: 10 A max; AC-15: 6 A at 230 V / 3 A at 400 V; DC-12: 6 A at 60 V / 3 A at 110 V / 1 A at 220 V; DC-13: 10 A at 24 V / 2 A at 60 V / 1 A at 110 V / 0.3 A at 220 V |
| Product Description | Siemens SIRIUS S00 power contactor with a 110 V AC (50/60 Hz) coil, designed for dependable switching of three-phase loads. It provides three normally open main contacts plus one normally open auxiliary contact, with AC-1 current up to 22 A and AC-3 motor duty up to 9 A (4 kW at 400 V). Screw terminals and DIN-rail mounting make it a practical choice for compact control panels. |
This is a 3‑pole power contactor used to switch loads such as three‑phase motors and resistive heaters from a low-power control signal. It is commonly used as the main switching element in motor starter circuits and automation panels.
It uses an AC control coil rated at 110 V AC, 50/60 Hz. The coil operating range factor is 0.8–1.1 at 50 Hz and 0.85–1.1 at 60 Hz.
It has 3 main normally-open (NO) power poles and 1 built-in NO auxiliary contact.
Typical ratings include 22 A at AC‑1 (400 V, 40 °C) and 9 A at AC‑3 (400 V). Always size according to the duty category and the application conditions.
For motor switching (AC‑3), it is typically suitable for 4 kW at 400 V, 4.5 kW at 500 V, and up to 5.5 kW at 690 V (application and installation conditions apply).
It can be used for certain DC duties, but the permissible DC current depends strongly on the utilisation category and how many main current paths are placed in series. For example, at DC‑1 with 1 current path it is rated 2.1 A at 110 V, while series paths can increase the permissible current for some configurations.
It is a compact S00 frame contactor. It supports screw mounting and snap-on mounting onto a 35 mm DIN rail (DIN EN 50022), and it is suitable for side-by-side mounting.
Typical overall dimensions are 45 mm wide, 57.5 mm high, and 72 mm deep.
The front and terminal areas are rated IP20, meaning it is finger-safe when correctly installed in a panel, but it is not sealed against dust or water ingress.
The screw terminals accept a range of conductor sizes. For the main and auxiliary terminals, typical ranges include solid or stranded conductors up to 2x (0.75–4 mm²) depending on the wiring arrangement, and AWG conductors up to 1x 12 (with certain combinations).
Typical operating ambient temperature range is -25 to +60 °C, with a maximum installation altitude of 2,000 m above sea level.
Yes. Typical upstream fuse guidance includes gL/gG 35 A for coordination type 1 and gL/gG 20 A for coordination type 2 for the main circuit, and gL/gG 10 A for the auxiliary switch circuit (selection must match the overall circuit design).
A typical minimum side clearance to earthed/grounded parts is 6 mm.
Typical mechanical service life is around 30,000,000 switching cycles for the contactor itself. When auxiliary blocks or electronics-compatible auxiliary blocks are added, the typical mechanical life figure can be lower.
Typical apparent pull-in power is 27 VA and apparent holding power is 4.4 VA for the AC coil.
Yes, it can be used as part of a reversing starter arrangement when paired with a second contactor and appropriate mechanical/electrical interlocking to prevent simultaneous closure.
This S00 contactor platform supports add-on auxiliary contact blocks. The standard unit includes 1 NO auxiliary contact, and additional signalling contacts can be added using compatible S00 accessories (verify configuration against your panel requirements).
A typical figure is 0.7 W per conductor at AC‑3, 400 V, at the rated operating current.
Check the required coil voltage (110 V AC), duty category (such as AC‑3 for motors), load current, switching frequency, installation temperature, and panel layout constraints. If you need to reference the exact device in documentation, you can cite Siemens 3RT1016-1AF01 in your bill of materials.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.