steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 weeks ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Schneider Electric |
| Part number | XAPD1201 |
| Product range | Harmony XAP |
| Product type | Die-cast empty control station |
| Device short name | XAPD |
| Intended application | Designed for 22 mm control and signalling devices |
| Enclosure material | Die-cast zinc construction for a robust metal housing |
| Enclosure colour | Grey, RAL 7035, on both base and cover |
| Front plate size | 80 x 80 mm |
| Overall dimensions | 80 mm width x 80 mm height x 51.5 mm depth |
| Usable depth | 49 mm |
| Number of cut-outs | 1 |
| Cut-out size | 22 mm diameter |
| Layout | 1 vertical row and 1 horizontal row |
| Control station style | Metal enclosure |
| Cable entries | 2 cable gland entries to ISO format |
| Thread type | M20 x 1.5 |
| IP protection rating | IP65, IP66 and IP69 to EN/IEC 60529 and EN/IEC 60947-5-1 |
| UL enclosure rating | UL Type 4 and Type 4X to UL 50 E |
| Impact protection | IK07 to IEC/EN 62262 |
| Electrical protection class | Class I to IEC/EN 61140 |
| Protective treatment | TC |
| Operating temperature | -25 °C to 70 °C |
| Storage temperature | -40 °C to 70 °C |
| Resistance to chemical agents | Special treatment available on request |
| Certifications | UL, cULus and EAC |
| Net weight | 0.455 kg |
| GTIN | 3389118039759 |
| Country of origin | MA |
This is a die-cast empty control station designed for industrial control and signalling applications. It is intended to house one 22 mm operator and provides a robust metal enclosure for panel-mounted control devices.
No. It is supplied as an empty enclosure only, so the push button, selector switch, pilot light or other 22 mm device must be selected separately. Schneider XAPD1201 is designed as the housing for that assembly.
The enclosure has one 22 mm cut-out, so it is suitable for a single control or signalling unit.
The front plate measures 80 x 80 mm, and the overall depth is 51.5 mm. The usable internal depth is 49 mm, which helps when checking fit for the chosen operator and wiring arrangement.
The housing is made from die-cast zinc, giving it a more durable and rigid construction than many lighter-duty enclosure options.
The base and cover are grey, finished to RAL 7035.
The enclosure is rated IP65, IP66 and IP69 when assembled correctly with suitable components and cable entries. This makes it suitable for demanding industrial environments where dust and water resistance are important.
It uses two cable gland entry points with M20 x 1.5 thread format. This gives flexibility when planning cable routing into the station.
Yes. The dimensional information shows one hole with a blanking plug and one hole without a blanking plug for cable gland installation, which can help when configuring the enclosure for the application.
It is intended for standard 22 mm control and signalling units.
It is a metal control station. The die-cast zinc body offers a solid enclosure option where a tougher construction is preferred.
The enclosure has two fixing holes of 5.6 mm diameter with a depth of 19 mm. The single cut-out is positioned centrally, which helps with straightforward vertical mounting layouts.
The operating temperature range is -25 to +70 °C. For storage, the stated range is -40 to +70 °C.
Yes. It is rated IK07 for impact protection.
Yes. The enclosure is listed with UL, cULus and EAC certifications, and it is also stated with UL Type 4 and Type 4X protection classifications.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.