steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | IMD-IM400 |
| Manufacturer | Schneider |
| Part Category | Insulation Tester |
| Part Family | Vigilohm |
| Application | The Schneider IMD-IM400 is designed for marine and standard environmental applications, providing reliable insulation monitoring for large or highly disturbed networks. |
| Electrical Circuit | Suitable for IT grounding systems and large or highly disturbed networks. |
| Network Voltage | 0…480 V AC at 45-440 Hz (connected to phase), 0…830 V AC at 45-440 Hz (connected to neutral), 0…480 V DC |
| Measurement Type | Network insulation resistance (10 Ohm to 10 MOhm), Earth fault capacitance (0.1 to 500 µF) |
| Local Signalling | Green light for satisfactory insulation resistance, white for below prevention threshold, red for wiring/internal fault, yellow for insulation fault, yellow flashing for communication. |
| Threshold Setting | Pre-alarm: 1 kOhm to 1 MOhm, Alarm: 40 Ohm to 500 kOhm |
| Time Delay Range | 0 to 120 minutes for signal circuit |
| Auxiliary Supply | 100 to 440 V AC 50/60 Hz ±15%, 100 to 440 V AC 400 Hz ±15%, 100 to 440 V DC ±15% |
| Power Consumption | 25 VA |
| Dielectric Strength | 4000 V AC, 5500 V DC |
| IP Degree of Protection | Case: IP20, Front face: IP54 |
| Operating Altitude | Up to 3000 m |
| Pollution Degree | 2 |
| Relative Humidity | 0…90% |
| Installation Type | Indoor |
| Standards | IEC 60364-4-41, IEC 61010-1, IEC 61557-8, CSA C22.2 No 14-05, IEC 60364-5-51, UL 508 |
| Product Certifications | DNV, RMRS, CE, ABS, EAC, CSA, cULus, UL |
| Operating Temperature | -25 to 55 °C |
| Storage Temperature | -40 to 70 °C |
| Material | Thermoplastic |
| Dimensions | Height: 123 mm, Width: 159 mm, Depth: 90 mm |
| Net Weight | 0.75 kg |
| Mounting Position | Horizontal |
| Connections | Removable screw terminal block, 0.2…2.5 mm² |
| Environmental Characteristics | Conforms to IEC 60068-2-30 for exposure to damp heat not in service, IEC 60068-2-56 for exposure to damp heat in service, and IEC 60068-2-52 for salt mist. |
| Sustainable Offer Status | Green Premium product, compliant with REACh and RoHS regulations, mercury-free. |
The primary function of the Schneider IMD-IM400 insulation tester is to monitor the insulation resistance in electrical networks, ensuring safety and reliability by detecting insulation faults.
The insulation tester is suitable for large or highly disturbed networks, making it ideal for marine applications and standard environmental applications.
The Schneider IMD-IM400 can handle network voltages from 0 to 480 V AC at 45 to 440 Hz when connected to the phase, and up to 830 V AC when connected to the neutral. It also supports DC voltages up to 480 V.
The insulation tester can operate in ambient temperatures ranging from -25 to 55 °C and can be stored in temperatures from -40 to 70 °C. It is designed for indoor installation and can function at altitudes up to 3000 meters.
The Schneider IMD-IM400 has dimensions of 123 mm in height, 159 mm in width, and 90 mm in depth, with a net weight of 0.75 kg.
The insulation tester complies with several standards, including IEC 60364-4-41, IEC 61010-1, IEC 61557-8, CSA C22.2 No 14-05, IEC 60364-5-51, and UL 508. It is also certified by DNV, RMRS, CE, ABS, EAC, CSA, cULus, and UL.
The Schneider IMD-IM400 offers an IP20 degree of protection for the case and IP54 for the front face, ensuring protection against dust and water ingress.
The insulation tester has a power consumption of 25 VA.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.