steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
1 month ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Schneider |
| Part Number | C12F34V160L |
| Product Type | Earth leakage circuit breaker |
| Product Range | ComPacT NSXm new generation |
| Device Short Name | NSXm 160F |
| Application | Electrical distribution |
| Poles | 3P |
| Protected Poles | 3D |
| Rated Current | 160 A at 40 °C |
| Rated Operational Voltage | 440 V AC, 50/60 Hz |
| Network Type | AC |
| Network Frequency | 50/60 Hz |
| Isolation Suitability | Suitable for isolation according to IEC 60947-2 |
| Utilisation Category | Category A |
| Performance Level | F, 36 kA at 415 V AC |
| Rated Ultimate Short-Circuit Breaking Capacity | 85 kA at 220–240 V AC, 36 kA at 380–415 V AC, 35 kA at 440 V AC |
| Rated Service Short-Circuit Breaking Capacity | 85 kA at 220–240 V AC, 36 kA at 380–415 V AC, 30 kA at 440 V AC |
| Trip Unit | MicroLogic 4.1 |
| Trip Unit Technology | Electronic |
| Protection Functions | LSoIR |
| Control Type | Toggle |
| Mounting Mode | Fixed |
| Mounting Support | Backplate |
| Mounting Position | Horizontal or vertical, flat on the back |
| Connection Type | Front connection for upper and lower terminals |
| Terminals | EverLink lug terminals |
| Cable Size | 2.5–70 mm² fine stranded copper; 2.5–95 mm² rigid or stranded aluminium/copper |
| Connection Pitch | 35 mm with spreaders, 27 mm without spreaders |
| Module Width | 9 modules of 9 mm |
| Rated Insulation Voltage | 500 V AC, 50/60 Hz |
| Rated Impulse Withstand Voltage | 8 kV |
| Long-Time Protection Adjustment | Adjustable Ir with 9 settings, 63–160 A |
| Long-Time Protection Delay | Fixed delay: 200 s at 1.5 x Ir, 8 s at 6 x Ir, 5 s at 7.2 x Ir |
| Short-Time Protection Adjustment | Adjustable Isd with 9 settings, 1.5–10 x Ir |
| Instantaneous Protection | Fixed Ii at 2000 A |
| Earth Leakage Protection | Integrated |
| Earth Leakage Class | Class A and Class AC |
| Earth Leakage Sensitivity | Adjustable IΔn: 30 mA, 100 mA, 300 mA, 500 mA, 1 A, 3 A, 5 A |
| Earth Leakage Time Delay | Adjustable Δt: 0 ms, 60 ms, 150 ms, 500 ms, 1000 ms |
| Thermal Memory | 20 minutes before and after tripping |
| Auxiliary Slots | 1 slot for OF auxiliary switch, 1 slot for SD alarm switch, 1 slot for MN or MX voltage release |
| Local Signalling | Green flag for auxiliary contact presence |
| Mechanical Durability | 20,000 cycles |
| Electrical Durability | 20,000 cycles at 440 V In/2; 10,000 cycles at 440 V In; 10,000 cycles at 690 V In/2; 5,000 cycles at 690 V In |
| Power Dissipation | 12.21 W per pole |
| Standards | EN/IEC 60947 |
| Pollution Degree | 3 according to IEC 60664-1 |
| IP Degree of Protection | IP40 according to IEC 60529 |
| IK Degree of Protection | IK07 according to IEC 62262 |
| Operating Temperature | -25 to 70 °C |
| Storage Temperature | -40 to 85 °C |
| Relative Humidity | 0–95% |
| Operating Altitude | 2000 m without derating, 5000 m with derating |
| Dimensions | 108 mm width x 144 mm height x 80 mm depth |
| Net Weight | 1.63 kg |
| Colour | Grey, RAL 7016 |
| Commodity Code | 853620 |
This is an earth leakage circuit breaker from the ComPacT NSXm new generation range, designed for electrical distribution applications. It combines overcurrent protection with integrated earth leakage protection.
The rated current is 160 A at 40 °C. The trip unit also allows long-time current adjustment across a 63 A to 160 A range.
It is a 3-pole breaker with 3 protected poles, making it suitable for three-phase AC distribution circuits.
The rated operational voltage is 440 V AC at 50/60 Hz.
It has an ultimate short-circuit breaking capacity of 36 kA at 380–415 V AC and 35 kA at 440 V AC. At 220–240 V AC, the rated ultimate breaking capacity is 85 kA.
The breaker is fitted with a MicroLogic 4.1 electronic trip unit. For C12F34V160L, this provides LSoIR protection functions, including long-time, short-time, instantaneous and earth leakage protection.
The earth leakage sensitivity is adjustable, with settings including 30 mA, 100 mA, 300 mA, 500 mA, 1 A, 3 A and 5 A depending on the selected protection class.
Yes. The earth leakage protection time delay is adjustable with settings of 0 ms, 60 ms, 150 ms, 500 ms and 1000 ms.
The EverLink terminals accept fine stranded copper cable from 2.5 mm² to 70 mm², and rigid or stranded aluminium or copper cable from 2.5 mm² to 95 mm².
The breaker measures 108 mm wide, 144 mm high and 80 mm deep, with a net weight of approximately 1.63 kg.
The breaker can be mounted horizontally or vertically, flat on the back. The upper and lower connections are both made from the front.
It is rated IP40 and IK07, with an operating temperature range of -25 °C to 70 °C. It can operate up to 2000 metres without derating and up to 5000 metres with derating.
The breaker conforms to EN/IEC 60947, with isolation suitability stated in accordance with IEC 60947-2.
Yes. It has slots for an OF auxiliary switch, an SD alarm switch and an MN or MX voltage release.
The unit is grey, with the colour reference RAL 7016.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.