steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 weeks ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | C1034V100 |
| Manufacturer | Schneider |
| Product Range | ComPacT NSX100...250 new generation |
| Product Type | Trip unit |
| Trip Unit Name | MicroLogic 4.2 |
| Trip Unit Technology | Electronic |
| Application | Distribution |
| Poles Description | 3P |
| Protected Poles Description | 3D |
| Trip Unit Protection Functions | LSoIR (Long-time, Short-time, Instantaneous, Earth-leakage protection) |
| Trip Unit Rating | 100 A at 40 °C |
| Rated Operational Voltage | 440 V AC 50/60 Hz |
| Network Type | AC |
| Network Frequency | 50/60 Hz |
| Circuit Breaker Mounting Mode | Fixed |
| Long-time Protection Pick-up Adjustment | Adjustable, 9 settings (40...100 A) |
| Long-time Protection Delay Adjustment | Fixed (11 s at 7.2 x Ir, 16 s at 6 x Ir, 400 s at 1.5 x Ir) |
| Thermal Memory | 20 minutes before and after tripping |
| Short-time Protection Pick-up Adjustment | Adjustable (1.5...10 x Ir) |
| Short-time Protection Delay Adjustment | Fixed |
| Instantaneous Protection Pick-up Adjustment | Fixed (1500 A) |
| Earth-leakage Protection | Integrated, Class A, Adjustable sensitivity (0.03 A to 5 A) |
| Earth-leakage Protection Time Delay Adjustment | Adjustable (0 ms to 1 s) |
| Zone Selective Interlocking | Without |
| Local Signalling | Flashing LED (green) for ready to operate, LED 105 % Ir (red) for overload, LED 90 % Ir (orange) for overload, Colour indicator (yellow) for residual current |
| Standards | EN/IEC 60947-2 |
| Electrical Shock Protection Class | Class II |
| Pollution Degree | 3 conforming to IEC 60947-1 |
| IP Degree of Protection | IP40 conforming to IEC 60529 |
| Ambient Air Temperature for Operation | -25…70 °C |
| Ambient Air Temperature for Storage | -40…85 °C |
| Packaging | Package 1: Height 9.5 cm, Width 11.0 cm, Length 15.0 cm, Weight 602.0 g; Package 2: Height 30.0 cm, Width 30.0 cm, Length 40.0 cm, Weight 6.41 kg |
| Environmental Impact | Carbon footprint: 19 kg CO2 eq., Packaging made with recycled cardboard, Contains halogens above thresholds |
The Schneider C1034V100 is a trip unit designed for circuit breakers, providing electronic protection with a rating of 100A. It is used for distribution applications and offers various protection functions including overload, short-circuit, and earth-leakage protection.
This part offers LSoIR protection, which includes long-time overload protection, short-time short-circuit protection with fixed delay, instantaneous short-circuit protection, and earth-leakage protection.
The rated operational voltage for the Schneider C1034V100 is 440 V AC, suitable for 50/60 Hz networks.
This part is designed with 3 poles, providing comprehensive protection for three-phase systems.
Yes, the earth-leakage protection sensitivity is adjustable, with a range from 0.03 A to 5 A.
The ambient air temperature for operation ranges from -25°C to 70°C, making it suitable for various environmental conditions.
The Schneider C1034V100 has an IP40 degree of protection, conforming to IEC 60529 standards.
The thermal memory feature retains information for 20 minutes before and after tripping, ensuring accurate protection and response to overload conditions.
Yes, the short-time protection pick-up is adjustable, with a range of 1.5 to 10 times the long-time protection pick-up setting.
This part complies with EN/IEC 60947-2 standards, ensuring reliable performance and safety in electrical installations.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.