What type of connector does this cordset use?
It uses an M12 × 1 female connector with A-coding in a right-angle (angled) format, with 4 pins for standard sensor/actuator connectivity.
How long is the cable?
The cable length is 5 metres (Turck catalogue part 6625026).
What is the cable jacket material and colour?
The outer jacket is PVC and the standard jacket colour is black.
What are the electrical ratings?
Rated voltage is 250 V, rated current is 4 A, and the dielectric test voltage is 2000 V (all specified at +20 °C).
What ingress protection rating does it provide?
The connector assembly is rated IP67 and IP69K when correctly mated and tightened (protection rating applies only in the connected state).
What conductor size and construction are used?
It is a 4-core cable with 4 × 0.34 mm² conductors, using a stranded construction of 42 × 0.1 mm per core.
What are the core colours?
Core colours are BN (brown), WH (white), BU (blue), and BK (black), matching typical 4-pin A-coded sensor wiring conventions.
What is the cable diameter?
The overall cable diameter is Ø 4.6 mm ± 0.20 mm.
What temperature range can it operate in?
For fixed (static) installation: -40 to +105 °C ambient. For flexible (moving) use: -5 to +80 °C ambient.
What is the recommended minimum bending radius?
For stationary installation it is at least 5× the cable diameter, and for flexible use at least 10× the cable diameter. With a Ø 4.6 mm cable, this is approximately ``5 × 4.6 mm ≈ 23 mm`` (static) and ``10 × 4.6 mm ≈ 46 mm`` (dynamic).
Is the cordset suitable for environments with oils or chemicals?
Yes. The PVC jacket is specified as resistant to chemicals and oils, and also resistant to acidic and alkaline solutions, as well as microbial influence and hydrolysis.
What sealing material is used at the connector?
The sealing material is FPM/FKM, commonly used for robust resistance in industrial environments.
Does the connector have any approvals?
It is listed with cULus certification according to the product datasheet.
How durable is the connector for repeated mating?
Mechanical lifetime is specified as greater than 100 mating cycles.