steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Schneider Electric |
| Part Number | A9F94250 |
| Product Type | Miniature circuit breaker (MCB) |
| Product Range | Acti9 |
| Device Model | iC60L |
| Description | Two-pole, 50 A miniature circuit breaker with C-curve thermal-magnetic tripping for overload and short-circuit protection in electrical distribution circuits. |
| Number of Poles | 2 |
| Protected Poles | 2 |
| Rated Current | 50 A |
| Tripping Characteristic | C curve |
| Trip Technology | Thermal-magnetic |
| Network Compatibility | AC and DC |
| Network Frequency | 50/60 Hz |
| Ultimate Breaking Capacity (Icu), AC | 30 kA at 220–240 V AC; 15 kA at 380–415 V AC; 10 kA at 440 V AC, according to EN/IEC 60947-2 |
| Ultimate Breaking Capacity (Icu), DC | 20 kA at up to 125 V DC, according to EN/IEC 60947-2 |
| Service Breaking Capacity (Ics), AC | 15 kA at 220–240 V AC; 7.5 kA at 380–415 V AC; 5 kA at 440 V AC |
| Rated Insulation Voltage | 500 V AC |
| Rated Impulse Withstand Voltage | 6 kV |
| Utilisation Category | Category A |
| Isolation Capability | Suitable for isolation according to EN/IEC 60947-2 |
| Operation | Manual toggle |
| Indication | Contact position indicator and trip indicator |
| Mounting | Fixed mounting on DIN rail |
| Busbar Compatibility | Comb busbar and distribution block connection at the top or bottom |
| Terminal Type | Single terminals at the top and bottom |
| Rigid Conductor Capacity | 1–35 mm² |
| Flexible Conductor Capacity | 1–25 mm² |
| Wire Stripping Length | 14 mm |
| Terminal Tightening Torque | 3.5 N·m |
| Earth-Leakage Protection | Requires a separate block |
| Dimensions | 85 mm height × 36 mm width × 78.5 mm depth |
| Net Weight | 0.25 kg |
| Colour | White |
| Mechanical Durability | 20,000 operating cycles |
| Electrical Durability | 10,000 operating cycles |
| Degree of Protection | IP20 according to EN/IEC 60529 |
| Pollution Degree | 3 |
| Overvoltage Category | IV |
| Operating Temperature | −35 to +70 °C |
| Storage Temperature | −40 to +85 °C |
| Relative Humidity | 95% at 55 °C |
| Operating Altitude | 0–2,000 m |
| Applicable Standards | EN 60947-2; IEC 60947-2 |
The A9F94250 is an Acti9 iC60L miniature circuit breaker with two protected poles, a 50 A rated current and a C-curve tripping characteristic. Its thermal-magnetic trip mechanism provides protection against overloads and short circuits in electrical distribution circuits.
The C curve defines the circuit breaker's response to short-duration overcurrents. The datasheet specifies a magnetic tripping limit of eight times the rated current, with a tolerance of ±20%. Suitability depends on the circuit's starting currents and protection requirements.
Yes. This is a two-pole circuit breaker with protection on both poles, rather than a single protected pole paired with an unprotected neutral.
Yes. The A9F94250 is specified for both AC and DC networks. Its breaking capacity varies with the network voltage and current type, so the applicable rating must be checked against the intended circuit.
The rated ultimate short-circuit breaking capacity, Icu, is 30 kA at 220–240 V AC, 15 kA at 380–415 V AC and 10 kA at 440 V AC, at 50/60 Hz. For DC applications, the specified Icu is 20 kA at up to 125 V DC. These ratings are stated in accordance with EN/IEC 60947-2.
The circuit breaker mounts on a DIN rail. It is compatible with comb busbars and distribution blocks at either the top or bottom, allowing flexibility when arranging a distribution assembly.
The circuit breaker measures 85 mm high, 36 mm wide and 78.5 mm deep. It occupies four 9 mm pitches and has a net weight of 0.25 kg.
The top and bottom terminals accept rigid conductors from 1 to 35 mm² and flexible conductors from 1 to 25 mm². The specified wire stripping length is 14 mm, and the terminal tightening torque is 3.5 N·m.
No. The circuit breaker provides thermal-magnetic overcurrent protection. Earth-leakage protection requires a separate compatible block; it is not built into this device.
The device has a contact position indicator and a local trip indicator. A toggle provides manual operation.
The specified ambient operating temperature range is −35°C to +70°C, and the storage temperature range is −40°C to +85°C. The stated operating altitude range is 0–2,000 metres, and the degree of protection is IP20.
The A9F94250 is specified to IEC 60947-2 and EN 60947-2. The datasheet also states suitability for isolation under these standards.
The stated mechanical durability is 20,000 operating cycles, while the electrical durability is 10,000 operating cycles. These are durability ratings rather than a prediction of operating life in a particular installation.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.