steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 weeks ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Schneider Electric |
| Part Number | 140ARI03010 |
| Product Range / Family | Modicon Quantum |
| Product Type | Analogue input module for RTD temperature measurement, designed to bring multi-channel temperature sensing into a Modicon Quantum PLC I/O rack |
| Number of Inputs | 8 analogue inputs |
| Input Type | Differential |
| Supported Sensor Types | RTD: Pt 100 / Pt 200 / Pt 500 / Pt 1000; RTD: Ni 100 / Ni 200 / Ni 500 / Ni 1000 |
| Temperature Measurement Ranges (RTD, configurable) | Pt RTD: -100…450 °C; Pt RTD: -200…850 °C; Ni RTD: -60…180 °C |
| Excitation / Measurement Modes (RTD) | 0.5 mA (Ni 100 / 200 / 500 / 1000); 2.5 mA (Pt 100 / 200 and Ni 100 / 200) |
| Resolution | 13 bits |
| Addressing Requirement | 9 input words |
| Input Impedance | ≥ 10 MΩ |
| Absolute Accuracy Error | 0.1 °C |
| Linearity Error | ±0.01% of full scale; ±0.5 °C |
| Accuracy Drift vs Ambient Temperature | ±0.5 °C at 25 °C; ±0.9 °C across 0…60 °C |
| Channel-to-Bus Isolation | 1780 V AC (47…63 Hz, 60 s); 2500 V DC (60 s) |
| Channel-to-Channel Isolation | 300 Vrms AC |
| Update Time | 640 ms (2-wire / 4-wire); 1200 ms (3-wire) |
| Fault Detection | Broken wire; overrange (overtacking scale) |
| Local Indication | 1 green LED (bus active); 1 red LED (external fault); 8 green LEDs (channel on); 8 red LEDs (channel fault) |
| Backplane (Bus) Current Requirement | 200 mA |
| Power Dissipation | 1 W (module) |
| Mounting Location | Any slot in a Modicon Quantum rack |
| Connection Type | 140XTS00200 |
| Marking | CE |
| Standards / Certifications (as stated) | UL 508; CSA C22.2 No 142; FM Class 1 Division 2; cUL |
| ESD Immunity | 4 kV contact; 8 kV air (IEC 801-2) |
| Immunity to Electromagnetic Fields | 10 V/m, 80…1000 MHz (IEC 801-3) |
| Operating Ambient Temperature | 0…60 °C |
| Storage Ambient Temperature | -40…85 °C |
| Relative Humidity | Up to 95% (non-condensing) |
| Operating Altitude | ≤ 5000 m |
| Module Format | Standard |
| Dimensions (H × W × D) | 250.0 mm × 40.3 mm × 103.9 mm |
| Net Weight | 0.3 kg |
It is an analogue input module designed for temperature measurement using RTD sensors. It provides 8 differential input channels and converts RTD signals into digital values for the PLC to read.
It supports RTD temperature probes including Pt 100, Pt 200, Pt 500, Pt 1000 and Ni 100, Ni 200, Ni 500, Ni 1000, depending on the selected measurement range and excitation mode.
There are 8 analogue input channels, each using differential measurement. Differential inputs measure the voltage difference between two terminals per channel, which helps reduce sensitivity to common-mode noise compared with single-ended measurement.
The module provides 13-bit analogue input resolution for its RTD measurement functions.
It supports 2-wire, 3-wire, and 4-wire RTD wiring. The chosen wiring method affects performance and update time.
Update time is 640 ms for 2-wire/4-wire RTD wiring and 1200 ms for 3-wire RTD wiring.
It requires 9 input words for addressing within the PLC configuration.
It supports fault detection including broken wire and overtracking scale conditions, helping identify wiring issues or out-of-range measurements.
It includes LED indication for bus communication (Active), an external fault indicator, and per-channel LEDs showing channel on status and channel fault status (8 green and 8 red for the channels).
Bus current requirement is 200 mA, and typical power dissipation is 1 W.
Isolation between channels and bus is rated at 1780 V AC (47–63 Hz) for 60 seconds and 2500 V DC for 60 seconds. Isolation between channels is 300 Vrms AC.
Operating ambient air temperature is 0–60 °C, storage temperature is -40–85 °C, relative humidity is up to 95% (non-condensing), and operating altitude is up to 5000 m.
It can be mounted in any slot in a Modicon Quantum rack, allowing flexible placement alongside other I/O modules.
The specified connection type is 140XTS00200, which is the terminal assembly used for wiring RTD inputs to the module.
The module is a standard-format Quantum module with approximate dimensions of 250.0 mm (height) x 103.9 mm (width) x 40.3 mm (depth). Net weight is approximately 0.3 kg (for reference: Schneider 140ARI03010).
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.