What safety levels can the PMCprotego S2-2 implement?
The PMCprotego S2-2 is capable of implementing safety level SIL 2 in accordance with EN/IEC 62061, ensuring reliable performance in failsafe applications.
Which safety functions are supported by this servo amplifier safety card?
This safety card supports a range of safety functions including STO (Safe Torque Off), SS1 (Safe Stop 1), SS2 (Safe Stop 2), SOS (Safe Operating Stop), SLS (Safely Limited Speed), SSR (Safe Speed Range), SDI (Safe Direction), and SLI (Safe Limited Increment).
Can you describe the environmental suitability of the PMCprotego S2-2?
The PMCprotego S2-2 is suitable for various climatic conditions, meeting standards such as EN 60068-2-30 and EN 60068-2-78, and can operate within an ambient temperature range of 0 - 40 °C.
What are the electrical specifications for the inputs and outputs of this part?
The inputs of the PMCprotego S2-2 have a signal level at 0 of -3 to +5 VDC and a U input to EN 61131-2 Type 1 of 24 V DC. The semiconductor outputs can tolerate external voltage DC S/C of -15% to +20%, and the S/C output is short circuit proof.
What materials are used in the construction of the PMCprotego S2-2?
The front plate of the housing is made from steel 1.4016, and the upper part is constructed from polyester film, ensuring durability and reliability.
What are the dimensions and weight of this safety card?
The PMCprotego S2-2 has a height of 142 mm, a width of 18.5 mm, and a depth of 103 mm. It has a net weight of 150 g and a gross weight of 170 g.
What is the protection type standard for the PMCprotego S2-2?
The protection type standard for the PMCprotego S2-2 is EN 60529, which specifies the degrees of protection provided by enclosures for electrical equipment.
What is the significance of the Harmonized System Code for this part?
The Harmonized System Code, specifically 85389091 for the PMCprotego S2-2, is used for customs and international trade classification, which can be relevant for logistics and compliance purposes.